Luong, John H. T. - Abstract:
- Abstract: Benzalkonium chloride (BAK) is a mixture of alkyl benzyl dimethyl ammonium chlorides, which is used primarily as a biocide, surfactant, preservative, and antimicrobial agent in the pharmaceutical industry, in particular in ophthalmologic and nasal solutions. However, BAK may cause harmful consequences on the eye structures of the anterior segment. Control of BAK identity and content is necessary by applying a sensitive detection method. This study unravels the use of a glassy carbon (GC) electrode and a pristine boron‐doped diamond electrode (BDD) for the detection of four BAK homologs in a non‐aqueous medium using square wave voltammetry (SWV). The BDD provided more reproducibility of the oxidation potential than GC with a correlation coefficient of 0.999. The irreversible oxidation peak was very broad and deconvoluted into 3 peaks corresponding to C12, C14, and combined C16 –C18 to reflect their concentration ratio in the mixture. The method was then extended to the detection of the C12 homolog in the ophthalmic formulations with a limit of detection (LOD) of 0.4 μg/mL. The estimated BAK levels in three ophthalmic formulations were in agreement with the specified values by the manufacturers. The results were validated by high‐performance liquid chromatography (HPLC) with ultraviolet (UV) detection, confirming the presence of a single homolog (C12 ) in the eye drops. Abstract :
- Is Part Of:
- Electroanalysis. Volume 33:Issue 5(2021)
- Journal:
- Electroanalysis
- Issue:
- Volume 33:Issue 5(2021)
- Issue Display:
- Volume 33, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2021-0033-0005-0000
- Page Start:
- 1137
- Page End:
- 1142
- Publication Date:
- 2021-03-31
- Subjects:
- Benzalkonium chloride -- electrochemical method -- boron-doped diamond electrode -- C12 homologs -- high-performance liquid chromatography -- eye drops
Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.202060582 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22516.xml