Walking cadence required to elicit criterion moderate-intensity physical activity is moderated by fitness status. Issue 17 (2nd September 2019)
- Record Type:
- Journal Article
- Title:
- Walking cadence required to elicit criterion moderate-intensity physical activity is moderated by fitness status. Issue 17 (2nd September 2019)
- Main Title:
- Walking cadence required to elicit criterion moderate-intensity physical activity is moderated by fitness status
- Authors:
- Abt, Grant
Bray, James
Myers, Tony
Benson, Amanda C. - Abstract:
- ABSTRACT: The aims of this study were to estimate the walking cadence required to elicit a VO2 reserve (VO2 R) of 40% and determine if fitness status moderates the relationship between walking cadence and %VO2 R. Twenty participants (10 male, mean( s ) age 32(10) years; VO2 max 45(10) mL·kg −1 ·min −1 ) completed resting and maximal oxygen consumption tests prior to 7 x 5-min bouts of treadmill walking at increasing speed while wearing an Apple Watch and measuring oxygen consumption continuously. The 7 x 5-min exercise bouts were performed at speeds between 3 and 6 km·h −1 with 5-min seated rest following each bout. Walking cadence measured at each treadmill speed was recorded using the Apple Watch "Activity" app. Using Bayesian regression, we predict that participants need a walking cadence of 138 to 140 steps·min −1 to achieve a VO2 R of 40%. However, these values are moderated by fitness status such that those with lower fitness can achieve 40% VO2 R at a slower walking cadence. The results suggest that those with moderate fitness need to walk at ~40% higher than the currently recommended walking cadence (100 steps·min −1 ) to elicit moderate-intensity physical activity. However, walking cadence required to achieve moderate-intensity physical activity is moderated by fitness status.
- Is Part Of:
- Journal of sports sciences. Volume 37:Issue 17(2019)
- Journal:
- Journal of sports sciences
- Issue:
- Volume 37:Issue 17(2019)
- Issue Display:
- Volume 37, Issue 17 (2019)
- Year:
- 2019
- Volume:
- 37
- Issue:
- 17
- Issue Sort Value:
- 2019-0037-0017-0000
- Page Start:
- 1989
- Page End:
- 1995
- Publication Date:
- 2019-09-02
- Subjects:
- Wearable electronic devices -- exercise -- oxygen consumption -- walking -- Bayes theorem
Sports -- Periodicals
Sports -- Physiological aspects -- Periodicals
Sports -- Psychological aspects -- Periodicals
612.044 - Journal URLs:
- http://www.tandfonline.com/toc/rjsp20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/02640414.2019.1612505 ↗
- Languages:
- English
- ISSNs:
- 0264-0414
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22511.xml