A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report. (6th June 2022)
- Record Type:
- Journal Article
- Title:
- A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report. (6th June 2022)
- Main Title:
- A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report
- Authors:
- Murcia-Asensio, Antonio
Ferrero-Manzanal, Francisco
Sanz-Ruiz, Pablo
Cañada-Oya, Hermenegildo
Lax-Pérez, Raquel
Goetze, Christian - Other Names:
- Li Da sen Academic Editor.
- Abstract:
- Abstract : Introduction . Reconstruction of acetabular bone defects by the combination of trabecular metal augments and porous cups can be complex when extensive bone loss and poor-quality bone exists. The onset of porous cups with an interlocking mechanism may simplify surgical technique due to its superior initial mechanical stability. We endorse the possibility for a change in the classical order of setting of the augments and the cup. Methods . We present a technical modification and a series of cases of three patients with Paprosky IIB and IIIA acetabular defects operated with a combination of porous metal augments and a porous cup. In all the three patients, the setting of the cup was done first and secured with locked screws, and then the augments were set in place as a wedge and fixed with screws in a standard fashion. Results . The postoperative X-ray showed good position of implants with restoration of the center of rotation, and the patients had good recovery. Radiological evaluation in the midterm follow-up did not show mobilization of implants. Discussion . The use of metal porous augments is widely used for severe acetabular defects, being a versatile system to adapt to the different size defects. Nevertheless, its use may be technically demanding and time consuming. It is not infrequent that the setting of the augments conditions the final position of the cup with a possible interference with initial stability and eventually bone ingrowth of the cup. TheAbstract : Introduction . Reconstruction of acetabular bone defects by the combination of trabecular metal augments and porous cups can be complex when extensive bone loss and poor-quality bone exists. The onset of porous cups with an interlocking mechanism may simplify surgical technique due to its superior initial mechanical stability. We endorse the possibility for a change in the classical order of setting of the augments and the cup. Methods . We present a technical modification and a series of cases of three patients with Paprosky IIB and IIIA acetabular defects operated with a combination of porous metal augments and a porous cup. In all the three patients, the setting of the cup was done first and secured with locked screws, and then the augments were set in place as a wedge and fixed with screws in a standard fashion. Results . The postoperative X-ray showed good position of implants with restoration of the center of rotation, and the patients had good recovery. Radiological evaluation in the midterm follow-up did not show mobilization of implants. Discussion . The use of metal porous augments is widely used for severe acetabular defects, being a versatile system to adapt to the different size defects. Nevertheless, its use may be technically demanding and time consuming. It is not infrequent that the setting of the augments conditions the final position of the cup with a possible interference with initial stability and eventually bone ingrowth of the cup. The interlocking mechanism offers an additional biomechanical stability and thus may allow us to place the cup first in the desired position with a less demanding technique. Conclusion . With the use of locked-screw porous metal cups, the order of setting of implants may be changed in order to obtain a better restoration of the center of rotation and increased host-bone implant contact with a simplified surgical technique. … (more)
- Is Part Of:
- Case reports in orthopedics. Volume 2022(2022)
- Journal:
- Case reports in orthopedics
- Issue:
- Volume 2022(2022)
- Issue Display:
- Volume 2022, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 2022
- Issue:
- 2022
- Issue Sort Value:
- 2022-2022-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-06
- Subjects:
- Orthopedics -- Periodicals
Orthopedics
Orthopedics
Periodicals
Electronic journals
Periodicals
616.7 - Journal URLs:
- https://www.hindawi.com/journals/crior/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1948/ ↗
http://bibpurl.oclc.org/web/48966 ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%22EGTH%22&scope=site ↗ - DOI:
- 10.1155/2022/4062172 ↗
- Languages:
- English
- ISSNs:
- 2090-6749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 22454.xml