Seismic evaluation and calculation models of CFDST column blind bolted to composite beam joints with partial shear interaction. (1st October 2019)
- Record Type:
- Journal Article
- Title:
- Seismic evaluation and calculation models of CFDST column blind bolted to composite beam joints with partial shear interaction. (1st October 2019)
- Main Title:
- Seismic evaluation and calculation models of CFDST column blind bolted to composite beam joints with partial shear interaction
- Authors:
- Guo, Lei
Wang, Jingfeng
Wang, Wanqian
Duan, Mengjun - Abstract:
- Highlights: Seismic tests on partial shear composite joints to CFDST column were conducted. Typical failure modes of the partial shear blind bolted joint were characterized. Calculation models were proposed to inspect the mechanical behavior of the connection. Abstract: With the purpose of investigating the seismic performance and failure mechanism of the concrete filled double skin steel tubular (CFDST) column blind bolted to composite beam joint with partial shear interaction, an experimental campaign was carried out to assert the effects of end plate type and column hollow ratio. Each specimen was tested subjected to cyclic lateral loads. Typical failure modes of this novel joint in conjunction with the application of partial shear interaction were examined. Based on the experimental results, the crack patterns of steel bar truss deck (SBTD) concrete slabs and hysteretic performance were also estimated. Shift of the beam neutral axis was evaluated by the analyses of the strain distributions. Furthermore, calculation models of the blind bolted composite connections to circular CFDST columns with partial shear interaction were developed based on the component method, where the sagging and hogging moments were both incorporated. For partial shear joints, the shear connector was identified as an important component to estimate its influence on the initial stiffness and moment resistance. In addition, the lower bound of the degree of shear connection was proposed to avoid theHighlights: Seismic tests on partial shear composite joints to CFDST column were conducted. Typical failure modes of the partial shear blind bolted joint were characterized. Calculation models were proposed to inspect the mechanical behavior of the connection. Abstract: With the purpose of investigating the seismic performance and failure mechanism of the concrete filled double skin steel tubular (CFDST) column blind bolted to composite beam joint with partial shear interaction, an experimental campaign was carried out to assert the effects of end plate type and column hollow ratio. Each specimen was tested subjected to cyclic lateral loads. Typical failure modes of this novel joint in conjunction with the application of partial shear interaction were examined. Based on the experimental results, the crack patterns of steel bar truss deck (SBTD) concrete slabs and hysteretic performance were also estimated. Shift of the beam neutral axis was evaluated by the analyses of the strain distributions. Furthermore, calculation models of the blind bolted composite connections to circular CFDST columns with partial shear interaction were developed based on the component method, where the sagging and hogging moments were both incorporated. For partial shear joints, the shear connector was identified as an important component to estimate its influence on the initial stiffness and moment resistance. In addition, the lower bound of the degree of shear connection was proposed to avoid the shear connector fracture under sagging moment. The predicted results from the proposed component-based models were validated by the experimental data, which demonstrated that the derived calculation models were capable of evaluating the initial stiffness and moment resistances of the CFDST column blind bolted joints to composite beams with partial shear interaction. The experimental and analytical results provide a reference for the analysis and design of blind bolted composite joint to CFDST column with partial shear interaction in engineering practice. … (more)
- Is Part Of:
- Engineering structures. Volume 196(2019)
- Journal:
- Engineering structures
- Issue:
- Volume 196(2019)
- Issue Display:
- Volume 196, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 196
- Issue:
- 2019
- Issue Sort Value:
- 2019-0196-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10-01
- Subjects:
- Concrete-filled double skin steel tubular -- Composite joint -- Partial shear interaction -- Component-based model -- Blind bolt
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2019.06.005 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22439.xml