Clinical impact of a novel device delivery system in the diagnosis of bile duct lesions: A single‐center experience. Issue 7 (20th April 2022)
- Record Type:
- Journal Article
- Title:
- Clinical impact of a novel device delivery system in the diagnosis of bile duct lesions: A single‐center experience. Issue 7 (20th April 2022)
- Main Title:
- Clinical impact of a novel device delivery system in the diagnosis of bile duct lesions: A single‐center experience
- Authors:
- Matsumori, Tomoaki
Uza, Norimitsu
Shiokawa, Masahiro
Maruno, Takahisa
Nishikawa, Yoshihiro
Morita, Toshihiro
Kuwada, Takeshi
Marui, Saiko
Okada, Hirokazu
Taura, Kojiro
Kodama, Yuzo
Seno, Hiroshi - Other Names:
- Sang Hoon Ahn guestEditor.
- Abstract:
- Abstract: Background and Aim: Pathological evaluation is essential for the diagnosis of biliary tract diseases. However, existing evaluation methods have various challenges in terms of operability and diagnostic performance. The present study aimed to evaluate the feasibility, utility, and safety of a novel device delivery system for bile duct biopsy. Methods: This study was conducted as a retrospective, descriptive analysis at a single center. Overall, 25 examinations in 14 consecutive patients who underwent transpapillary biopsies for biliary lesions using the novel device delivery system from July to November 2020 were reviewed. Number and time of biopsy, technical success rate, adequate tissue sampling rate, adverse events, and diagnostic performance of bile duct biopsies using the novel device were evaluated. Moreover, negative surgical margins were assessed in patients who underwent surgical resection after mapping biopsy. Results: The median number of biopsy samples was five (range: 2–13), with a median biopsy time of 11.6 min. The technical success rate was 100% (140/140), with an adequate sampling rate of 82.9% (116/140). These rates did not differ depending on the biopsy site or purpose. There were no serious adverse events related to the procedures. The diagnostic sensitivity, specificity, and accuracy of biliary stricture were 90%, 100%, and 92.3%, respectively. Negative surgical margins were confirmed in all patients undergoing surgical resection, including oneAbstract: Background and Aim: Pathological evaluation is essential for the diagnosis of biliary tract diseases. However, existing evaluation methods have various challenges in terms of operability and diagnostic performance. The present study aimed to evaluate the feasibility, utility, and safety of a novel device delivery system for bile duct biopsy. Methods: This study was conducted as a retrospective, descriptive analysis at a single center. Overall, 25 examinations in 14 consecutive patients who underwent transpapillary biopsies for biliary lesions using the novel device delivery system from July to November 2020 were reviewed. Number and time of biopsy, technical success rate, adequate tissue sampling rate, adverse events, and diagnostic performance of bile duct biopsies using the novel device were evaluated. Moreover, negative surgical margins were assessed in patients who underwent surgical resection after mapping biopsy. Results: The median number of biopsy samples was five (range: 2–13), with a median biopsy time of 11.6 min. The technical success rate was 100% (140/140), with an adequate sampling rate of 82.9% (116/140). These rates did not differ depending on the biopsy site or purpose. There were no serious adverse events related to the procedures. The diagnostic sensitivity, specificity, and accuracy of biliary stricture were 90%, 100%, and 92.3%, respectively. Negative surgical margins were confirmed in all patients undergoing surgical resection, including one patient with a surgical procedure changed based on the results of mapping biopsy. Conclusions: The novel device delivery system has potentials in diagnosing biliary tract diseases and determining appropriate treatment strategies. … (more)
- Is Part Of:
- Journal of gastroenterology and hepatology. Volume 37:Issue 7(2022)
- Journal:
- Journal of gastroenterology and hepatology
- Issue:
- Volume 37:Issue 7(2022)
- Issue Display:
- Volume 37, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2022-0037-0007-0000
- Page Start:
- 1360
- Page End:
- 1366
- Publication Date:
- 2022-04-20
- Subjects:
- bile duct biopsy -- endoscopic retrograde cholangiopancreatography -- EndoSheather -- mapping biopsy
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Liver Diseases -- Periodicals
616.33 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1440-1746 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jgh ↗ - DOI:
- 10.1111/jgh.15866 ↗
- Languages:
- English
- ISSNs:
- 0815-9319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4987.615000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22376.xml