MRA of the Supraaortic Vasculature: Comparison of Gadobutrol and Gadoterate Meglumine at 1.5 T. Issue 2 (25th December 2021)
- Record Type:
- Journal Article
- Title:
- MRA of the Supraaortic Vasculature: Comparison of Gadobutrol and Gadoterate Meglumine at 1.5 T. Issue 2 (25th December 2021)
- Main Title:
- MRA of the Supraaortic Vasculature: Comparison of Gadobutrol and Gadoterate Meglumine at 1.5 T
- Authors:
- Cerne, John W.
Pathrose, Ashitha
Singer, Alyssa M.
Moore, Jackson E.
Serhal, Ali
Aouad, Pascale
Umair, Muhammad
Ragin, Ann
Allen, Bradley D.
Avery, Ryan
Markl, Michael
Carr, James C. - Abstract:
- Abstract : Background: Gadobutrol (GB) and gadoterate meglumine (GM) are contrast agents used for contrast‐enhanced magnetic resonance angiography (CEMRA). Supraaortic vasculature (SAV) CEMRAs are used to evaluate stroke risk and neurologic symptoms. There is a need to compare the SAV CEMRA image quality obtained with GB and GM. Purpose: To intra‐individually compare MRA images obtained with equimolar GB and GM at 1.5 T in the SAV. Study Type: Prospective, crossover. Population: Twenty‐eight subjects (54 ± 13 years; 17 female). Field Strength/Sequence: 1.5 T; three‐dimensional (3D) gradient recalled echo. Assessment: Quantitative image quality was measured by normalized signal intensity (SIn ) [SIn = SI blood/SD blood] and contrast ratio (CR) [CR = SI blood/SI muscle], determined by an observer (JWC) with 1 year of vascular imaging experience. Three radiologists (AS, PA, and MU) with (5, 5, and 6 years of) vascular imaging experience evaluated image quality by Likert‐scale ratings (of image impression, wall conspicuity, and artifact absence). Statistical Tests: SIn and CR were compared with paired t ‐tests or Wilcoxon signed‐rank tests and Bland–Altman plots. Qualitative ratings were compared with Wilcoxon signed‐rank test. Results: No significant difference in SIn was found between GB and GM. CRs with GB were significantly higher than GM at the right common carotid (6.9 ± 2.5 vs. 4.8 ± 1), left internal carotid (7.3 ± 2 vs. 4.4 ± 1.2), right internal carotid (7.7 ± 2.2 vs.Abstract : Background: Gadobutrol (GB) and gadoterate meglumine (GM) are contrast agents used for contrast‐enhanced magnetic resonance angiography (CEMRA). Supraaortic vasculature (SAV) CEMRAs are used to evaluate stroke risk and neurologic symptoms. There is a need to compare the SAV CEMRA image quality obtained with GB and GM. Purpose: To intra‐individually compare MRA images obtained with equimolar GB and GM at 1.5 T in the SAV. Study Type: Prospective, crossover. Population: Twenty‐eight subjects (54 ± 13 years; 17 female). Field Strength/Sequence: 1.5 T; three‐dimensional (3D) gradient recalled echo. Assessment: Quantitative image quality was measured by normalized signal intensity (SIn ) [SIn = SI blood/SD blood] and contrast ratio (CR) [CR = SI blood/SI muscle], determined by an observer (JWC) with 1 year of vascular imaging experience. Three radiologists (AS, PA, and MU) with (5, 5, and 6 years of) vascular imaging experience evaluated image quality by Likert‐scale ratings (of image impression, wall conspicuity, and artifact absence). Statistical Tests: SIn and CR were compared with paired t ‐tests or Wilcoxon signed‐rank tests and Bland–Altman plots. Qualitative ratings were compared with Wilcoxon signed‐rank test. Results: No significant difference in SIn was found between GB and GM. CRs with GB were significantly higher than GM at the right common carotid (6.9 ± 2.5 vs. 4.8 ± 1), left internal carotid (7.3 ± 2 vs. 4.4 ± 1.2), right internal carotid (7.7 ± 2.2 vs. 5 ± 1.1), and left vertebral (6.6 ± 2.2 vs. 4.5 ± 1.1) arteries. Bland–Altman plots showed relatively greater differences between GB and GM at higher CRs and SIn s. GM showed significantly higher artifact than GB (3.56 ± 0.52 vs. 3.36 ± 0.46) and significantly lower overall image quality (10.73 ± 1.45 vs. 11.26 ± 1.58) at the left vertebral artery. Data Conclusion: At 1.5 T and equimolar demonstration, GB (0.1 mL/kg, i.e., 0.1 mmol/kg) showed higher CRs in the SAV compared to GM (0.2 mL/kg, i.e., 0.1 mmol/kg) at most vessels. Subjective image quality was not significantly different between the two agents for most vessels. Level of Evidence: 2 Technical Efficacy: Stage 2 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 56:Issue 2(2022)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 56:Issue 2(2022)
- Issue Display:
- Volume 56, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2022-0056-0002-0000
- Page Start:
- 440
- Page End:
- 449
- Publication Date:
- 2021-12-25
- Subjects:
- supraaortic vasculature -- gadobutrol -- gadoterate meglumine
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.28044 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22375.xml