Endocapsular artificial iris implantation for iris defects: Reducing symptoms, restoring visual function and improving cosmesis. (26th April 2022)
- Record Type:
- Journal Article
- Title:
- Endocapsular artificial iris implantation for iris defects: Reducing symptoms, restoring visual function and improving cosmesis. (26th April 2022)
- Main Title:
- Endocapsular artificial iris implantation for iris defects: Reducing symptoms, restoring visual function and improving cosmesis
- Authors:
- Crawford, Alexandra Z.
Freundlich, Simone E. N.
Lim, Joevy
McGhee, Charles N. J. - Abstract:
- Abstract: Background: To investigate repair of iris defects by endocapsular implantation of an artificial iris, in relation to visual outcomes, safety profile and patient satisfaction. Methods: Retrospective, consecutive case series from Greenlane tertiary teaching hospital and Eye Institute, Auckland, New Zealand. Medical records of patients implanted with an endocapsular artificial iris were reviewed and followed for minimum 3 months. Patient characteristics, surgical management, clinical outcomes and subjective responses were recorded. Results: Nineteen artificial irises were implanted in 18 patients. Etiologies were iris melanotic lesion excision (73.7%), trauma (10.5%), congenital aniridia (10.5%) and Urrets‐Zavalia syndrome (5.3%). During postoperative follow‐up [14.1 ± 12.4 months (range: 3 to 59 months)], best corrected visual acuity (BCVA) and intraocular pressure (IOP) did not change significantly [BCVA, 0.23 logarithm of the minimum angle of resolution (logMAR) (20/32 Snellen) preoperatively vs. 0.18 logMAR postoperatively (20/25 Snellen) (Z = −0.222, p = 0.824); IOP, 15 mmHg preoperatively vs. 17 mmHg postoperatively (Z = 1.377, p = 0.1447)]. Mild or self‐limiting complications included: elevated IOP (42.1%), cystoid macular oedema (15.8%); persisting postoperative uveitis (15.8%) and minor vaulting of the prosthesis (15.7%). Moderate or severe complications included significant vaulting of prosthesis requiring surgical revision (5.3%) and a single eye (5.3%)Abstract: Background: To investigate repair of iris defects by endocapsular implantation of an artificial iris, in relation to visual outcomes, safety profile and patient satisfaction. Methods: Retrospective, consecutive case series from Greenlane tertiary teaching hospital and Eye Institute, Auckland, New Zealand. Medical records of patients implanted with an endocapsular artificial iris were reviewed and followed for minimum 3 months. Patient characteristics, surgical management, clinical outcomes and subjective responses were recorded. Results: Nineteen artificial irises were implanted in 18 patients. Etiologies were iris melanotic lesion excision (73.7%), trauma (10.5%), congenital aniridia (10.5%) and Urrets‐Zavalia syndrome (5.3%). During postoperative follow‐up [14.1 ± 12.4 months (range: 3 to 59 months)], best corrected visual acuity (BCVA) and intraocular pressure (IOP) did not change significantly [BCVA, 0.23 logarithm of the minimum angle of resolution (logMAR) (20/32 Snellen) preoperatively vs. 0.18 logMAR postoperatively (20/25 Snellen) (Z = −0.222, p = 0.824); IOP, 15 mmHg preoperatively vs. 17 mmHg postoperatively (Z = 1.377, p = 0.1447)]. Mild or self‐limiting complications included: elevated IOP (42.1%), cystoid macular oedema (15.8%); persisting postoperative uveitis (15.8%) and minor vaulting of the prosthesis (15.7%). Moderate or severe complications included significant vaulting of prosthesis requiring surgical revision (5.3%) and a single eye (5.3%) with trabeculectomy and corneal graft failure. 94.4% of patients were very satisfied with the cosmesis and would be highly likely to have the procedure again. Conclusions: This study confirms that endocapsular insertion of an artificial iris is typically associated with good functional and cosmetic results and a relatively low risk of significant complications. … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 50:Number 5(2022)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 50:Number 5(2022)
- Issue Display:
- Volume 50, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 50
- Issue:
- 5
- Issue Sort Value:
- 2022-0050-0005-0000
- Page Start:
- 490
- Page End:
- 499
- Publication Date:
- 2022-04-26
- Subjects:
- artificial endocapsular iris implant -- artificial iris -- iris colour -- iris defect -- iris melanoma
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.14083 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22383.xml