Orthorhombic Non‐Perovskite CsPbI3 Microwires for Stable High‐Resolution X‐Ray Detectors. Issue 13 (1st May 2022)
- Record Type:
- Journal Article
- Title:
- Orthorhombic Non‐Perovskite CsPbI3 Microwires for Stable High‐Resolution X‐Ray Detectors. Issue 13 (1st May 2022)
- Main Title:
- Orthorhombic Non‐Perovskite CsPbI3 Microwires for Stable High‐Resolution X‐Ray Detectors
- Authors:
- Kundu, Soumya
Richtsmeier, Devon
Hart, Alexander
Yeddu, Vishal
Song, Zihao
Niu, Guangda
Thrithamarassery Gangadharan, Deepak
Dennis, Emma
Tang, Jiang
Voznyy, Oleksandr
Bazalova‐Carter, Magdalena
Saidaminov, Makhsud I. - Abstract:
- Abstract: X‐ray detectors are used widely, but they suffer from short operational stability and insufficient absorptivity of X‐ray photons. Here, a strategy for room‐temperature, solution‐grown δ‐CsPbI3 monocrystalline microwires exhibiting one of the highest linear X‐ray absorption coefficients among known semiconductors is reported. In a metal–semiconductor–metal architecture, δ‐CsPbI3 demonstrates one of the lowest detectable X‐ray dose rates at 33.3 nGyair s −1, enabled by its exceptionally low dark current density of 12 pA mm −2 . The detector remains stable following a continuous operation for a total accumulated dose of 1.44 × 10 6 Gyair, which is equivalent to 720 million chest X‐ray scans. The 1D crystalline nature of δ‐CsPbI3 enables a high X‐ray imaging resolution of 12.4 line pairs per millimeter (lp mm −1 ). Abstract : Solution‐grown non‐perovskite δ‐CsPbI3 microwire X‐ray sensors demonstrate the lowest detectable dose rate of 33.3 nGyair s −1 and operational stability to an accumulated dose of 1.44 × 10 6 Gyair, equivalent to 720 million chest X‐ray scans. The 1D crystalline nature of δ‐CsPbI3 leads to a high X‐ray imaging resolution of 12.4 line pairs per millimeter.
- Is Part Of:
- Advanced optical materials. Volume 10:Issue 13(2022)
- Journal:
- Advanced optical materials
- Issue:
- Volume 10:Issue 13(2022)
- Issue Display:
- Volume 10, Issue 13 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 13
- Issue Sort Value:
- 2022-0010-0013-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-05-01
- Subjects:
- lead halides -- low dark current -- low detection limit -- microwires -- radiation detectors -- X‐ray detectors
Optical materials -- Periodicals
Photonics -- Periodicals
620.11295 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2195-1071 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adom.202200516 ↗
- Languages:
- English
- ISSNs:
- 2195-1071
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.918600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22363.xml