Development and Validation of Measurement Traceability for In Situ Immunoassays. (15th February 2021)
- Record Type:
- Journal Article
- Title:
- Development and Validation of Measurement Traceability for In Situ Immunoassays. (15th February 2021)
- Main Title:
- Development and Validation of Measurement Traceability for In Situ Immunoassays
- Authors:
- Torlakovic, Emina E
Sompuram, Seshi R
Vani, Kodela
Wang, Lili
Schaedle, Anika K
DeRose, Paul C
Bogen, Steven A - Abstract:
- Abstract: Background: Immunoassays for protein analytes measured in situ support a $2 billion laboratory testing industry that suffers from significant interlaboratory disparities, affecting patient treatment. The root cause is that immunohistochemical testing lacks the generally accepted tools for analytic standardization, including reference standards and traceable units of measure. Until now, the creation of these tools has represented an insoluble technical hurdle. Methods: We address the need with a new concept in metrology—that is, linked traceability. Rather than calculating analyte concentration directly, which has proven too variable, we calculate concentration by measuring an attached fluorescein, traceable to NIST Standard Reference Material 1934, a fluorescein standard. Results: For validation, newly developed estrogen receptor (ER) calibrators were deployed in tandem with an array of 80 breast cancer tissue sections in a national external quality assessment program. Laboratory performance was assessed using both the ER standards and the tissue array. Similar to previous studies, the tissue array revealed substantial discrepancies in ER test results among the participating laboratories. The new ER calibrators revealed a broad range of analytic sensitivity, with the lower limits of detection ranging from 7310 to 74 790 molecules of ER. The data demonstrate, for the first time, that the variable test results correlate with analytic sensitivity, which can now beAbstract: Background: Immunoassays for protein analytes measured in situ support a $2 billion laboratory testing industry that suffers from significant interlaboratory disparities, affecting patient treatment. The root cause is that immunohistochemical testing lacks the generally accepted tools for analytic standardization, including reference standards and traceable units of measure. Until now, the creation of these tools has represented an insoluble technical hurdle. Methods: We address the need with a new concept in metrology—that is, linked traceability. Rather than calculating analyte concentration directly, which has proven too variable, we calculate concentration by measuring an attached fluorescein, traceable to NIST Standard Reference Material 1934, a fluorescein standard. Results: For validation, newly developed estrogen receptor (ER) calibrators were deployed in tandem with an array of 80 breast cancer tissue sections in a national external quality assessment program. Laboratory performance was assessed using both the ER standards and the tissue array. Similar to previous studies, the tissue array revealed substantial discrepancies in ER test results among the participating laboratories. The new ER calibrators revealed a broad range of analytic sensitivity, with the lower limits of detection ranging from 7310 to 74 790 molecules of ER. The data demonstrate, for the first time, that the variable test results correlate with analytic sensitivity, which can now be measured quantitatively. Conclusions: The reference standard enables precise interlaboratory alignment of immunohistochemistry test sensitivity for measuring cellular proteins in situ. The introduction of a reference standard and traceable units of measure for protein expression marks an important milestone. … (more)
- Is Part Of:
- Clinical chemistry. Volume 67:Number 5(2021)
- Journal:
- Clinical chemistry
- Issue:
- Volume 67:Number 5(2021)
- Issue Display:
- Volume 67, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 67
- Issue:
- 5
- Issue Sort Value:
- 2021-0067-0005-0000
- Page Start:
- 763
- Page End:
- 771
- Publication Date:
- 2021-02-15
- Subjects:
- reference standard -- immunohistochemistry -- in situ -- microbead -- fluorescein
Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1093/clinchem/hvab008 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22353.xml