Utilisation of poor-quality optical coherence tomography scans: adjustment algorithm from the Singapore Epidemiology of Eye Diseases (SEED) study. Issue 7 (15th February 2021)
- Record Type:
- Journal Article
- Title:
- Utilisation of poor-quality optical coherence tomography scans: adjustment algorithm from the Singapore Epidemiology of Eye Diseases (SEED) study. Issue 7 (15th February 2021)
- Main Title:
- Utilisation of poor-quality optical coherence tomography scans: adjustment algorithm from the Singapore Epidemiology of Eye Diseases (SEED) study
- Authors:
- Thakur, Sahil
Yu, Marco
Tham, Yih Chung
Majithia, Shivani
Soh, Zhi-Da
Fang, Xiao Ling
Cheung, Carol
Boey, Pui Yi
Aung, Tin
Wong, Tien Yin
Cheng, Ching-Yu - Abstract:
- Abstract : Purpose: To evaluate the effect of signal strength (SS) on optical coherence tomography (OCT) parameters, and devise an algorithm to adjust the effect, when acceptable SS cannot be obtained. Methods: 5085 individuals (9582 eyes), aged ≥40 years from the Singapore Epidemiology of Eye Diseases population-based study were included. Everyone underwent a standardised ocular examination and imaging with Cirrus HD-OCT. Effect of SS was evaluated using multiple structural breaks linear mixed-effect models. Expected change for increment in SS between 4 and 10 for individual parameter was calculated. Subsequently we devised and evaluated an algorithm to adjust OCT parameters to higher SS. Results: Average retinal nerve fibre layer (RNFL) thickness showed shift of 4.11 µm from SS of 5 to 6. Above 6, it increased by 1.72 and 3.35 µm to 7 and 8; and by 1.09 µm (per unit increase) above 8 SS. Average ganglion cell-inner plexiform layer (GCIPL) thickness shifted 5.15 µm from SS of 5 to 6. Above 6, increased by 0.94 µm from 7 to 8; and by 0.16 µm (per unit increase) above 8 SS. When compared with reference in an independent test set, the algorithm produced less systemic bias. Algorithm-adjusted average RNFL was 0.549 µm thinner than the reference, while the unadjusted one was 2.841 µm thinner (p<0.001). Algorithm-adjusted and unadjusted average GCIPL was 1.102 µm and 2.228 µm thinner (p<0.001). Conclusions: OCT parameters can be adjusted for poor SS using an algorithm. This canAbstract : Purpose: To evaluate the effect of signal strength (SS) on optical coherence tomography (OCT) parameters, and devise an algorithm to adjust the effect, when acceptable SS cannot be obtained. Methods: 5085 individuals (9582 eyes), aged ≥40 years from the Singapore Epidemiology of Eye Diseases population-based study were included. Everyone underwent a standardised ocular examination and imaging with Cirrus HD-OCT. Effect of SS was evaluated using multiple structural breaks linear mixed-effect models. Expected change for increment in SS between 4 and 10 for individual parameter was calculated. Subsequently we devised and evaluated an algorithm to adjust OCT parameters to higher SS. Results: Average retinal nerve fibre layer (RNFL) thickness showed shift of 4.11 µm from SS of 5 to 6. Above 6, it increased by 1.72 and 3.35 µm to 7 and 8; and by 1.09 µm (per unit increase) above 8 SS. Average ganglion cell-inner plexiform layer (GCIPL) thickness shifted 5.15 µm from SS of 5 to 6. Above 6, increased by 0.94 µm from 7 to 8; and by 0.16 µm (per unit increase) above 8 SS. When compared with reference in an independent test set, the algorithm produced less systemic bias. Algorithm-adjusted average RNFL was 0.549 µm thinner than the reference, while the unadjusted one was 2.841 µm thinner (p<0.001). Algorithm-adjusted and unadjusted average GCIPL was 1.102 µm and 2.228 µm thinner (p<0.001). Conclusions: OCT parameters can be adjusted for poor SS using an algorithm. This can potentially assist in diagnosis and monitoring of glaucoma when scans with acceptable SS cannot be acquired from patients in clinics. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 106:Issue 7(2022)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 106:Issue 7(2022)
- Issue Display:
- Volume 106, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 106
- Issue:
- 7
- Issue Sort Value:
- 2022-0106-0007-0000
- Page Start:
- 962
- Page End:
- 969
- Publication Date:
- 2021-02-15
- Subjects:
- glaucoma -- imaging -- optic nerve -- macula
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2020-317756 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22344.xml