Comparative performance assessment of a novel cogeneration solar-driven building energy system integrating with various district heating designs. (15th September 2020)
- Record Type:
- Journal Article
- Title:
- Comparative performance assessment of a novel cogeneration solar-driven building energy system integrating with various district heating designs. (15th September 2020)
- Main Title:
- Comparative performance assessment of a novel cogeneration solar-driven building energy system integrating with various district heating designs
- Authors:
- Behzadi, Amirmohammad
Arabkoohsar, Ahmad - Abstract:
- Highlights: The interaction of a novel system with various district heating grids is compared. Transient simulation is investigated using TRNSYS software. The extra annual hot water volume of the ultra-low temperature model is 402.86 m 3 . Ultra-low temperature district heating model found to be superior in all aspects. For the best model, the maximum overall efficiency of 74.51% is obtained in June. Abstract: In the present study, a novel solar-based building energy system, which is integrated with both electricity and district heating grids, is proposed and modeled. The solar system uses photovoltaic-thermal panels and has neither a battery nor a heat pump. The elimination of the battery and heat pump is proposed to reduce the cost of the system to motivate the building owners to adopt the solution as a cheaper energy system for their buildings. In this way, the building energy system would be able not only to produce a major portion of the heat and electricity demands of the households but also to supply its excess production to the grids to decrease the energy bill of the building. As district heating systems are on the verge of a transformation to their next generations, it is important to know how this system would respond to the future designs and standards of district heating systems. That is why the simulations are accomplished based on different district heating integration scenarios, i.e. existing, low-temperature, and ultralow-temperature district heatingHighlights: The interaction of a novel system with various district heating grids is compared. Transient simulation is investigated using TRNSYS software. The extra annual hot water volume of the ultra-low temperature model is 402.86 m 3 . Ultra-low temperature district heating model found to be superior in all aspects. For the best model, the maximum overall efficiency of 74.51% is obtained in June. Abstract: In the present study, a novel solar-based building energy system, which is integrated with both electricity and district heating grids, is proposed and modeled. The solar system uses photovoltaic-thermal panels and has neither a battery nor a heat pump. The elimination of the battery and heat pump is proposed to reduce the cost of the system to motivate the building owners to adopt the solution as a cheaper energy system for their buildings. In this way, the building energy system would be able not only to produce a major portion of the heat and electricity demands of the households but also to supply its excess production to the grids to decrease the energy bill of the building. As district heating systems are on the verge of a transformation to their next generations, it is important to know how this system would respond to the future designs and standards of district heating systems. That is why the simulations are accomplished based on different district heating integration scenarios, i.e. existing, low-temperature, and ultralow-temperature district heating systems. For doing the simulations and comparative analysis on the performance of the system in various dynamic operating conditions, TRNSYS software is employed. The results show that the ultralow-temperature district heating model is the most suitable case for integration with the proposed system. In this case, the building energy systems will supply over 400 m 3 hot water to the heat network and about 1940 kWh surplus electricity to the power grid over an entire year. Due to a lower panel temperature, the system produces the largest amounts of electricity and heat (3647.4 kWh and 9118.5 kWh) compared to the other two cases. The maximum overall efficiency values of 74.51%, 62.35%, and 52.35% for ultralow-, low-, and the 3rd generation-district heating models are achieved. … (more)
- Is Part Of:
- Energy conversion and management. Volume 220(2020)
- Journal:
- Energy conversion and management
- Issue:
- Volume 220(2020)
- Issue Display:
- Volume 220, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 220
- Issue:
- 2020
- Issue Sort Value:
- 2020-0220-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-15
- Subjects:
- PVT -- District heating system -- Low- and ultralow-temperature heat grids -- Smart building energy system -- Heat storage tank
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2020.113101 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22324.xml