A stir bar sorptive extraction device coupled with a gas chromatography flame ionization detector for the determination of abused prescription drugs in lean cocktail samples. Issue 26 (14th June 2022)
- Record Type:
- Journal Article
- Title:
- A stir bar sorptive extraction device coupled with a gas chromatography flame ionization detector for the determination of abused prescription drugs in lean cocktail samples. Issue 26 (14th June 2022)
- Main Title:
- A stir bar sorptive extraction device coupled with a gas chromatography flame ionization detector for the determination of abused prescription drugs in lean cocktail samples
- Authors:
- Nualdee, Kamonwan
Buain, Ratchaneekorn
Janchawee, Benjamas
Sukree, Warakorn
Thammakhet-Buranachai, Chongdee
Kanatharana, Proespichaya
Chaisiwamongkhol, Korbua
Prutipanlai, Sathaporn
Phonchai, Apichai - Abstract:
- Abstract : This work presents an in-house developed stir bar sorptive extraction (SBSE) device with an XAD-2 adsorbent followed by analysis using GC-FID for the extraction and determination of the five main abused prescription drugs in lean cocktail samples. Abstract : A lean cocktail is a mixed drink for the non-medical use of prescription medications that has emerged in recent years as a drug of abuse and is related to drug-facilitated crimes. The determination of active ingredients in a lean cocktail is necessary for forensic investigations. This work presents an in-house developed stir bar sorptive extraction (SBSE) device with an XAD-2 adsorbent followed by analysis using GC-FID for the extraction and determination of the five main abused prescription drugs (diphenhydramine, tramadol, chlorpheniramine, dextromethorphan and promethazine) in lean cocktail samples. Under optimized conditions, the developed method provided linearity for 1.0–250 μg mL −1 of each of the five abused prescription drugs. The limits of detection and limits of quantitation were in the respective ranges of 0.25–0.5 μg mL −1 and 1.0–1.5 μg mL −1 . The percentage of extraction was 85.0–94.9%. The intra-day and inter-day precisions were 1.2–14.4% RSD and 1.4–15.8% RSD, respectively. Good relative recoveries in the range of 86.7–110.3% and 88.5–107.9% were obtained when the proposed method was applied for extraction and analysis of abused prescription drugs in five lean cocktail samples. The developedAbstract : This work presents an in-house developed stir bar sorptive extraction (SBSE) device with an XAD-2 adsorbent followed by analysis using GC-FID for the extraction and determination of the five main abused prescription drugs in lean cocktail samples. Abstract : A lean cocktail is a mixed drink for the non-medical use of prescription medications that has emerged in recent years as a drug of abuse and is related to drug-facilitated crimes. The determination of active ingredients in a lean cocktail is necessary for forensic investigations. This work presents an in-house developed stir bar sorptive extraction (SBSE) device with an XAD-2 adsorbent followed by analysis using GC-FID for the extraction and determination of the five main abused prescription drugs (diphenhydramine, tramadol, chlorpheniramine, dextromethorphan and promethazine) in lean cocktail samples. Under optimized conditions, the developed method provided linearity for 1.0–250 μg mL −1 of each of the five abused prescription drugs. The limits of detection and limits of quantitation were in the respective ranges of 0.25–0.5 μg mL −1 and 1.0–1.5 μg mL −1 . The percentage of extraction was 85.0–94.9%. The intra-day and inter-day precisions were 1.2–14.4% RSD and 1.4–15.8% RSD, respectively. Good relative recoveries in the range of 86.7–110.3% and 88.5–107.9% were obtained when the proposed method was applied for extraction and analysis of abused prescription drugs in five lean cocktail samples. The developed method can be a useful tool for measuring the levels of abused prescription drugs in a lean cocktail and the data could also be used as evidence in a forensic investigation. … (more)
- Is Part Of:
- Analytical methods. Volume 14:Issue 26(2022)
- Journal:
- Analytical methods
- Issue:
- Volume 14:Issue 26(2022)
- Issue Display:
- Volume 14, Issue 26 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 26
- Issue Sort Value:
- 2022-0014-0026-0000
- Page Start:
- 2557
- Page End:
- 2568
- Publication Date:
- 2022-06-14
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ay00603k ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22326.xml