Photon beam energy dependent single-arc volumetric modulated arc optimization. (February 2021)
- Record Type:
- Journal Article
- Title:
- Photon beam energy dependent single-arc volumetric modulated arc optimization. (February 2021)
- Main Title:
- Photon beam energy dependent single-arc volumetric modulated arc optimization
- Authors:
- Momin, Shadab
Gräfe, James L.
Georgiou, Konstantinos
Khan, Rao F. - Abstract:
- Highlights: Mixed photon energy VMAT approach has the potential to improve dosimetric and radiobiological outcome in large size patients. A novel optimization framework for optimization of photon beam energy and arc lengths in VMAT is presented. The algorithm has the potential to select beam energy its contribution judiciously. Abstract: Purpose: The purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths. Methods and materials: Owing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD). Results: The contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP–VMAT notably improved bladder and rectum sparingHighlights: Mixed photon energy VMAT approach has the potential to improve dosimetric and radiobiological outcome in large size patients. A novel optimization framework for optimization of photon beam energy and arc lengths in VMAT is presented. The algorithm has the potential to select beam energy its contribution judiciously. Abstract: Purpose: The purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths. Methods and materials: Owing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD). Results: The contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP–VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP–VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP–VMAT either improved or maintained femoral heads compared to SE–VMAT. SAMP–VMAT reduced the nontarget tissue integral dose in all ten cases. Conclusions: A single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage. … (more)
- Is Part Of:
- Physica medica. Volume 82(2021)
- Journal:
- Physica medica
- Issue:
- Volume 82(2021)
- Issue Display:
- Volume 82, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 82
- Issue:
- 2021
- Issue Sort Value:
- 2021-0082-2021-0000
- Page Start:
- 122
- Page End:
- 133
- Publication Date:
- 2021-02
- Subjects:
- Single arc VMAT -- Multiple photon energy optimization -- Convex relaxation -- IMRT
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.02.004 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22330.xml