A novel particle-to-fluid direct-contact counter-flow heat exchanger for CSP power generation applications: Design features and experimental testing. (June 2021)
- Record Type:
- Journal Article
- Title:
- A novel particle-to-fluid direct-contact counter-flow heat exchanger for CSP power generation applications: Design features and experimental testing. (June 2021)
- Main Title:
- A novel particle-to-fluid direct-contact counter-flow heat exchanger for CSP power generation applications: Design features and experimental testing
- Authors:
- Alaqel, Shaker
Saleh, Nader S.
Djajadiwinata, Eldwin
Saeed, Rageh
Alswaiyd, Abdulelah
Al-Ansary, Hany
El-Leathy, Abdelrahman
Zeitoun, Obida
Jeter, Sheldon
Abdel-Khalik, Said
Khayyat, Ahmad
Danish, Syed
Al-Suhaibani, Zeyad - Abstract:
- Abstract: A novel particle-to-fluid direct-contact counter-flow heat exchanger (PFDCHX) is introduced and investigated. The proposed heat exchanger offers efficient integration with an air-breathing power cycle. A proposed particle-based power tower integrated system using the PFDCHX is presented. The PFDCHX system comprises two main parts: the particle handling unit (PHU) and the direct-contact heat exchanger (DCHX). The PHU delivers solid particles to the pressurized DCHX, a manifold assembly was deployed to separate particles into several separate streams to be injected at the upper end of the DCHX via several distributor pipes. Several enhancement features were considered to prevent particle carryover, including a tangential inlet for the pressurized air (at the bottom end of the DCHX), particle–air disengagement zone (at the top end of the DCHX), and a tapered-shaped heat exchange chamber. Results showed that, for tests with excessive particle flow rate, more than 80% of the temperature rise was achieved within 0.35 m above the air inlet, attributed to the tangential inlet's swirl flow pattern. The overall temperature rise along the heat exchanger was not significantly influenced by a change in operating air pressure from one barg to three barg. Highlights: A novel particle-to-air direct-contact heat exchanger is introduced-investigated. The added features overcome issues in the previous direct-contact heat exchangers. More than 80% of heat transfer occurred at 0.35 mAbstract: A novel particle-to-fluid direct-contact counter-flow heat exchanger (PFDCHX) is introduced and investigated. The proposed heat exchanger offers efficient integration with an air-breathing power cycle. A proposed particle-based power tower integrated system using the PFDCHX is presented. The PFDCHX system comprises two main parts: the particle handling unit (PHU) and the direct-contact heat exchanger (DCHX). The PHU delivers solid particles to the pressurized DCHX, a manifold assembly was deployed to separate particles into several separate streams to be injected at the upper end of the DCHX via several distributor pipes. Several enhancement features were considered to prevent particle carryover, including a tangential inlet for the pressurized air (at the bottom end of the DCHX), particle–air disengagement zone (at the top end of the DCHX), and a tapered-shaped heat exchange chamber. Results showed that, for tests with excessive particle flow rate, more than 80% of the temperature rise was achieved within 0.35 m above the air inlet, attributed to the tangential inlet's swirl flow pattern. The overall temperature rise along the heat exchanger was not significantly influenced by a change in operating air pressure from one barg to three barg. Highlights: A novel particle-to-air direct-contact heat exchanger is introduced-investigated. The added features overcome issues in the previous direct-contact heat exchangers. More than 80% of heat transfer occurred at 0.35 m above the air inlet. The temperature rise didn't change with varying the operating air pressure. The proposed heat exchanger can be integrated effectively-safely with power cycle. … (more)
- Is Part Of:
- Renewable energy. Volume 170(2021)
- Journal:
- Renewable energy
- Issue:
- Volume 170(2021)
- Issue Display:
- Volume 170, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 170
- Issue:
- 2021
- Issue Sort Value:
- 2021-0170-2021-0000
- Page Start:
- 905
- Page End:
- 926
- Publication Date:
- 2021-06
- Subjects:
- Particle-to-fluid heat exchanger -- Direct-contact heat exchanger -- Falling particles heat exchanger
Renewable energy sources -- Periodicals
Power resources -- Periodicals
Énergies renouvelables -- Périodiques
Ressources énergétiques -- Périodiques
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09601481 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/renewable-energy/ ↗ - DOI:
- 10.1016/j.renene.2021.02.049 ↗
- Languages:
- English
- ISSNs:
- 0960-1481
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7364.187000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22343.xml