The straw tracking detector for the Fermilab Muon g-2 Experiment. (1st February 2022)
- Record Type:
- Journal Article
- Title:
- The straw tracking detector for the Fermilab Muon g-2 Experiment. (1st February 2022)
- Main Title:
- The straw tracking detector for the Fermilab Muon g-2 Experiment
- Authors:
- King, B.T.
Albahri, T.
Al-Kilani, S.
Allspach, D.
Beckner, D.
Behnke, A.
Bowcock, T.J.V.
Boyden, D.
Carey, R.M.
Carroll, J.
Casey, B.C.K.
Charity, S.
Chislett, R.
Eads, M.
Epps, A.
Foster, S.B.
Gastler, D.
Grant, S.
Halewood-Leagas, T.
Hardin, K.
Hazen, E.
Hesketh, G.
Hollywood, D.J.
Jones, T.
Kenziora, C.
Keshavarzi, A.
Kiburg, M.
Kinnaird, N.
Kintner, J.
Lancaster, M.
Lucà, A.
Lukicov, G.
Luo, G.
Mapar, L.
Maxfield, S.J.
Mott, J.
Motuk, E.
Mourato, H.
Pohlman, N.
Price, J.
Roberts, B.L.
Sathyan, D.
Shenk, M.
Sim, D.
Stuttard, T.
Sweetmore, G.
Thayer, G.
Thomson, K.
Turner, W.
Vasilkova, D.
Velho, J.
Voirin, E.
Walton, T.
Warren, M.
Welty-Rieger, L.
Whitley, M.
Wormald, M.
… (more) - Abstract:
- Abstract: The Muon g -2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.
- Is Part Of:
- Journal of instrumentation. Volume 17:Number 2(2022)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 17:Number 2(2022)
- Issue Display:
- Volume 17, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 2
- Issue Sort Value:
- 2022-0017-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-01
- Subjects:
- Detector design and construction technologies and materials -- Manufacturing -- Particle tracking detectors (Gaseous detectors) -- Performance of High Energy Physics Detectors
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/17/02/P02035 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22340.xml