Subcutaneous adipose tissue thickness determination using ultrasound signals processing: A phantom study. (August 2022)
- Record Type:
- Journal Article
- Title:
- Subcutaneous adipose tissue thickness determination using ultrasound signals processing: A phantom study. (August 2022)
- Main Title:
- Subcutaneous adipose tissue thickness determination using ultrasound signals processing: A phantom study
- Authors:
- Hajiasgari, Mona
Setarehdan, Seyed Kamaledin
Rangraz, Parisa - Abstract:
- Abstract: According to the top priority of health and fitness, the ultrasound (US) technique for measuring subcutaneous adipose tissue (SAT), as an indicator for body composition analysis, has received the most attention. So, tissue segmentation was performed to determine the boundaries between skin, SAT, and muscle in phantoms with different layers, and thicknesses that were fabricated to simulate tissue layers. The pre-processing of the signal was carried out using wavelet transform (WT) and Hilbert transform for denoising and detection. After the processing step, using WT for signal decomposition, a neural network was trained based on the scan line signals to detect the SAT layer. The coordinates of the convex probe were converted to linear to reduce the time and increase the accuracy for creating the target matrix. The algorithm was designed for automatic measurements of deep (normal), superficial (random), and noisy SAT thickness. Statistical evaluation was done to assess the system's skill in tissue classification and measurement of SAT thickness. Results revealed that most of the features related to coarse levels of detail coefficients extracted from wavelet decomposition levels can be used to build a classifier that can be applied successfully to differentiate between SAT and non-SAT tissue regions with a mean classification accuracy of 94.3% for 20 mm and 92.4% for 4 mm SAT in random mode with the error of estimate 0.05% and 0.07% respectively. Also, using 3 medianAbstract: According to the top priority of health and fitness, the ultrasound (US) technique for measuring subcutaneous adipose tissue (SAT), as an indicator for body composition analysis, has received the most attention. So, tissue segmentation was performed to determine the boundaries between skin, SAT, and muscle in phantoms with different layers, and thicknesses that were fabricated to simulate tissue layers. The pre-processing of the signal was carried out using wavelet transform (WT) and Hilbert transform for denoising and detection. After the processing step, using WT for signal decomposition, a neural network was trained based on the scan line signals to detect the SAT layer. The coordinates of the convex probe were converted to linear to reduce the time and increase the accuracy for creating the target matrix. The algorithm was designed for automatic measurements of deep (normal), superficial (random), and noisy SAT thickness. Statistical evaluation was done to assess the system's skill in tissue classification and measurement of SAT thickness. Results revealed that most of the features related to coarse levels of detail coefficients extracted from wavelet decomposition levels can be used to build a classifier that can be applied successfully to differentiate between SAT and non-SAT tissue regions with a mean classification accuracy of 94.3% for 20 mm and 92.4% for 4 mm SAT in random mode with the error of estimate 0.05% and 0.07% respectively. Also, using 3 median filters and increasing their lengths from 3 to 7 improved the accuracy results to find SAT entry and exit boundaries. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 77(2022)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 77(2022)
- Issue Display:
- Volume 77, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 77
- Issue:
- 2022
- Issue Sort Value:
- 2022-0077-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-08
- Subjects:
- Ultrasound echo analysis -- RF data acquisition -- Subcutaneous adipose tissue characterization -- Wavelet transform -- Median filter -- Convert convex probe coordinates to linear
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2022.103744 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22352.xml