Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: A real world multicenter analysis. (1st September 2022)
- Record Type:
- Journal Article
- Title:
- Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: A real world multicenter analysis. (1st September 2022)
- Main Title:
- Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: A real world multicenter analysis
- Authors:
- Castro-Mejía, Alex F.
Amat-Santos, Ignacio
Ortega-Armas, Maria E.
Baz, Jose A.
Moreno, Raúl
Diaz, Jose F.
Travieso, Alejandro
Jimenez-Quevedo, Pilar
Santos-Martínez, Sandra
McInerney, Angela
Galeote, Guillermo
Díaz, Victor Alfonso Jimenez
Garrido, Jessica Roa
Tirado-Conte, Gabriela
Barrero, Alejandro
Marroquin, Luis
Nuñez-Gil, Ivan
Gonzalo, Nieves
Fernandez-Ortiz, Antonio
Escaned, Javier
Nombela-Franco, Luis - Abstract:
- Abstract: Background: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. Methods and results: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro ( n = 130), Acurate-neo ( n = 79), Portico ( n = 75) and Allegra ( n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms ( p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1–7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1–3.3, pAbstract: Background: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. Methods and results: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro ( n = 130), Acurate-neo ( n = 79), Portico ( n = 75) and Allegra ( n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms ( p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1–7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1–3.3, p = 0.015), while higher implantation (<3 mm (OR: 0.3, 95% IC 0.1–0.7, p = 0.014) and use of Acurate-Neo valve (OR: 0.4; 95% IC 0.2–0.8, p = 0.009) were protective factor. Conclusions: New generation self-expanding aortic valves were associated with a significant increase in PR and QRS interval at hospital discharge leading to a very high rate of HDCD. While valve recapture and implantation depth were independent predictors for the occurrence of HDCD, use of Accurate-Neo valve was a protective factor. Highlights: Conduction disturbances after TAVR are common with SEV. However electrocardiographic changes with new generation SEV have not been described. New generation SEV is associated with significant PR interval prolongation and QRS widening immediately post-TAVR and at discharge. While implantation depth and valve recapture were independent predictors of HDCD at discharge, Acurate-neo valve was associated with lower rates of HDCD. Baseline RBBB, valve recapture, low implantation depth and significant increase in PR interval and QRS widening post-TAVR, predicted a higher in-hospital PPM rate with a modest discriminatory ability. … (more)
- Is Part Of:
- International journal of cardiology. Volume 362(2022)
- Journal:
- International journal of cardiology
- Issue:
- Volume 362(2022)
- Issue Display:
- Volume 362, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 362
- Issue:
- 2022
- Issue Sort Value:
- 2022-0362-2022-0000
- Page Start:
- 128
- Page End:
- 136
- Publication Date:
- 2022-09-01
- Subjects:
- Transcatheter aortic valve replacement -- Self-expanding aortic valves -- Electrocardiographic disturbances -- Pacemaker
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2022.05.014 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: