Waveform-arranged multiple skin paddles: A novel design to reconstruct complex soft tissue defects of the extremities with a modified multi-lobed perforator flap. Issue 7 (July 2022)
- Record Type:
- Journal Article
- Title:
- Waveform-arranged multiple skin paddles: A novel design to reconstruct complex soft tissue defects of the extremities with a modified multi-lobed perforator flap. Issue 7 (July 2022)
- Main Title:
- Waveform-arranged multiple skin paddles: A novel design to reconstruct complex soft tissue defects of the extremities with a modified multi-lobed perforator flap
- Authors:
- Qing, Liming
Wu, Panfeng
Luo, Gaojie
Li, Xiaoxiao
Huang, Chengxiong
Yu, Fang
Tang, Juyu - Abstract:
- Abstract: Background: Multi-lobed perforator flap was one of popular approaches for one-stage reconstruction of complex soft tissue defects because of its minimal donor-site morbidity. However, the area of skin island that can be harvested on the donor site is limited on the angiosome distribution, Moreover, large defects require more than the conventional skin island provided by a traditional multi-lobed perforator flap. For further extended skin paddles, this study presented a novel design of waveform-arranged skin paddles to elevated a modified multi-lobed perforator flap for the reconstruction of complex soft tissue defects in the extremities. Methods: From March of 2015 to March of 2020, fifteen patients underwent complex soft tissue defects reconstruction with waveform-arranged multi-lobed perforator flaps. According the size, shape and localization of the defects, two strategies were performed to design this modified multi-lobed flap. Results: A total of fifteen waveform-arranged multi-lobed perforator flaps were successfully harvested to reconstruct complex soft tissue defects of the extremities. Among of them, Waveform–arranged dual skin paddles perforator flap were performed in eleven cases, and the waveform–arranged tripaddle perforator flaps were used in four cases. All the flaps survived and no flap related complication was observed postoperatively. The donor sites were closed directly in all cases. The mean follow-up time was 15.6 months. Most of the casesAbstract: Background: Multi-lobed perforator flap was one of popular approaches for one-stage reconstruction of complex soft tissue defects because of its minimal donor-site morbidity. However, the area of skin island that can be harvested on the donor site is limited on the angiosome distribution, Moreover, large defects require more than the conventional skin island provided by a traditional multi-lobed perforator flap. For further extended skin paddles, this study presented a novel design of waveform-arranged skin paddles to elevated a modified multi-lobed perforator flap for the reconstruction of complex soft tissue defects in the extremities. Methods: From March of 2015 to March of 2020, fifteen patients underwent complex soft tissue defects reconstruction with waveform-arranged multi-lobed perforator flaps. According the size, shape and localization of the defects, two strategies were performed to design this modified multi-lobed flap. Results: A total of fifteen waveform-arranged multi-lobed perforator flaps were successfully harvested to reconstruct complex soft tissue defects of the extremities. Among of them, Waveform–arranged dual skin paddles perforator flap were performed in eleven cases, and the waveform–arranged tripaddle perforator flaps were used in four cases. All the flaps survived and no flap related complication was observed postoperatively. The donor sites were closed directly in all cases. The mean follow-up time was 15.6 months. Most of the cases showed satisfactory contour. Conclusion: The waveform design of multi-lobed perforator flap was an alternative approach for reconstruction of complex soft tissue defects; it can maximize the harvested skin area of the donor site to provide extended skin island. … (more)
- Is Part Of:
- Injury. Volume 53:Issue 7(2022)
- Journal:
- Injury
- Issue:
- Volume 53:Issue 7(2022)
- Issue Display:
- Volume 53, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 53
- Issue:
- 7
- Issue Sort Value:
- 2022-0053-0007-0000
- Page Start:
- 2550
- Page End:
- 2556
- Publication Date:
- 2022-07
- Subjects:
- Soft tissue defects -- Perforator flap -- Extremity -- Microsurgery
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2022.05.040 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22321.xml