Challenges associated with retrospective analysis of left ventricular function using clinical echocardiograms from a multicenter research study. Issue 2 (24th January 2021)
- Record Type:
- Journal Article
- Title:
- Challenges associated with retrospective analysis of left ventricular function using clinical echocardiograms from a multicenter research study. Issue 2 (24th January 2021)
- Main Title:
- Challenges associated with retrospective analysis of left ventricular function using clinical echocardiograms from a multicenter research study
- Authors:
- Sachdeva, Ritu
Stratton, Kayla L.
Cox, David E.
Armenian, Saro H.
Bhat, Aarti
Border, William L.
Leger, Kasey J.
Leisenring, Wendy M.
Meacham, Lillian R.
Sadak, Karim T.
Narasimhan, Shanti
Chow, Eric J.
Nathan, Paul C. - Abstract:
- Abstract: Background: Retrospective multicenter research using echocardiograms obtained for routine clinical care can be hampered by issues of individual center quality. We sought to evaluate imaging and patient characteristics associated with poorer quality of archived echocardiograms from a cohort of childhood cancer survivors. Methods: A single blinded reviewer at a central core laboratory graded quality of clinical echocardiograms from five centers focusing on images to derive 2D and M‐mode fractional shortening (FS), biplane Simpson's ejection fraction (EF), myocardial performance index (MPI), tissue Doppler imaging (TDI)–derived velocities, and global longitudinal strain (GLS). Results: Of 535 studies analyzed in 102 subjects from 2004 to 2017, all measures of cardiac function could be assessed in only 7%. While FS by 2D or M‐mode, MPI, and septal E/E′ could be measured in >80% studies, mitral E/E′ was less consistent (69%), but better than EF (52%) and GLS (10%). 66% of studies had ≥1 issue, with technical issues (eg, lung artifact, poor endocardial definition) being the most common (33%). Lack of 2‐ and 3‐chamber views was associated with the performing center. Patient age <5 years had a higher chance of apex cutoff in 4‐chamber views compared with 16‐35 years old. Overall, for any quality issue, earlier era of echo and center were the only significant risk factors. Conclusion: Assessment of cardiac function using pooled multicenter archived echocardiograms wasAbstract: Background: Retrospective multicenter research using echocardiograms obtained for routine clinical care can be hampered by issues of individual center quality. We sought to evaluate imaging and patient characteristics associated with poorer quality of archived echocardiograms from a cohort of childhood cancer survivors. Methods: A single blinded reviewer at a central core laboratory graded quality of clinical echocardiograms from five centers focusing on images to derive 2D and M‐mode fractional shortening (FS), biplane Simpson's ejection fraction (EF), myocardial performance index (MPI), tissue Doppler imaging (TDI)–derived velocities, and global longitudinal strain (GLS). Results: Of 535 studies analyzed in 102 subjects from 2004 to 2017, all measures of cardiac function could be assessed in only 7%. While FS by 2D or M‐mode, MPI, and septal E/E′ could be measured in >80% studies, mitral E/E′ was less consistent (69%), but better than EF (52%) and GLS (10%). 66% of studies had ≥1 issue, with technical issues (eg, lung artifact, poor endocardial definition) being the most common (33%). Lack of 2‐ and 3‐chamber views was associated with the performing center. Patient age <5 years had a higher chance of apex cutoff in 4‐chamber views compared with 16‐35 years old. Overall, for any quality issue, earlier era of echo and center were the only significant risk factors. Conclusion: Assessment of cardiac function using pooled multicenter archived echocardiograms was significantly limited. Efforts to standardize clinical echocardiographic protocols to include apical 2‐ and 3‐chamber views and TDI will improve the ability to quantitate LV function. … (more)
- Is Part Of:
- Echocardiography. Volume 38:Issue 2(2021)
- Journal:
- Echocardiography
- Issue:
- Volume 38:Issue 2(2021)
- Issue Display:
- Volume 38, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 2
- Issue Sort Value:
- 2021-0038-0002-0000
- Page Start:
- 296
- Page End:
- 303
- Publication Date:
- 2021-01-24
- Subjects:
- 2D echocardiography -- left ventricular function -- strain rate imaging
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.14983 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22320.xml