Simple Method of Screening for Frailty in Older Adults Using a Chronometer and Tape Measure in Clinic. Issue 1 (4th January 2018)
- Record Type:
- Journal Article
- Title:
- Simple Method of Screening for Frailty in Older Adults Using a Chronometer and Tape Measure in Clinic. Issue 1 (4th January 2018)
- Main Title:
- Simple Method of Screening for Frailty in Older Adults Using a Chronometer and Tape Measure in Clinic
- Authors:
- Jung, Hee‐Won
Kang, Min‐Gu
Choi, Jung‐Yeon
Yoon, Sol‐Ji
Kim, Sun‐wook
Kim, Kwang‐il
Kim, Cheol‐Ho - Abstract:
- Abstract : Objectives: Detecting frailty in older adults scheduled for surgery is important to predict the occurrence of adverse outcomes, but because of its complexity, frailty screening is not commonly performed. The objective of the current study was to assess whether frailty can be screened for using automatically measured usual gait speed (UGS) and mid‐arm circumference (MAC) in the outpatient clinic. Design: Prospective, cross‐sectional study. Setting: Geriatric center of a tertiary hospital. Participants: Outpatients aged 65 and older (N = 113). Measurements: Frailty status was evaluated according to a multidimensional frailty score (MFS) using a comprehensive geriatric assessment, and participants were classified into 5 categories. UGS was evaluated by having participants walk through the clinic using an automated laser‐gated chronometer. MAC was recorded using a tape measure on a blood pressure cuff. Correlations between these two physical measurements and MFS were assessed. Results: The mean age of the 93 participants who successfully underwent UGS evaluation was 75.8 ± 4.7; 35 were male. In this population, the mean Charlson Comorbidity Index was 2.2 ± 1.4, mean MFS was 4.1 ± 2.0, and 20 participants were considered to be at high risk of experiencing adverse outcomes. Mean UGS was 0.75 ± 0.16 m/s, and mean MAC was 31.2 ± 1.9 cm); both physical parameters were correlated with MFS (UGS: standardized beta = −0.420, P < .001; MAC: standardized beta = −0.457, P <Abstract : Objectives: Detecting frailty in older adults scheduled for surgery is important to predict the occurrence of adverse outcomes, but because of its complexity, frailty screening is not commonly performed. The objective of the current study was to assess whether frailty can be screened for using automatically measured usual gait speed (UGS) and mid‐arm circumference (MAC) in the outpatient clinic. Design: Prospective, cross‐sectional study. Setting: Geriatric center of a tertiary hospital. Participants: Outpatients aged 65 and older (N = 113). Measurements: Frailty status was evaluated according to a multidimensional frailty score (MFS) using a comprehensive geriatric assessment, and participants were classified into 5 categories. UGS was evaluated by having participants walk through the clinic using an automated laser‐gated chronometer. MAC was recorded using a tape measure on a blood pressure cuff. Correlations between these two physical measurements and MFS were assessed. Results: The mean age of the 93 participants who successfully underwent UGS evaluation was 75.8 ± 4.7; 35 were male. In this population, the mean Charlson Comorbidity Index was 2.2 ± 1.4, mean MFS was 4.1 ± 2.0, and 20 participants were considered to be at high risk of experiencing adverse outcomes. Mean UGS was 0.75 ± 0.16 m/s, and mean MAC was 31.2 ± 1.9 cm); both physical parameters were correlated with MFS (UGS: standardized beta = −0.420, P < .001; MAC: standardized beta = −0.457, P < .001). Using UGS and MFS, the area under curve of receiver operating curve for determining which participants were at high risk of experiencing adverse outcomes was 0.809 ( P < .001). Conclusion: UGS and MAC are viable methods of clinically screening for frailty. … (more)
- Is Part Of:
- Journal of the American Geriatrics Society. Volume 66:Issue 1(2018)
- Journal:
- Journal of the American Geriatrics Society
- Issue:
- Volume 66:Issue 1(2018)
- Issue Display:
- Volume 66, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 66
- Issue:
- 1
- Issue Sort Value:
- 2018-0066-0001-0000
- Page Start:
- 157
- Page End:
- 160
- Publication Date:
- 2018-01-04
- Subjects:
- screening -- frail elderly -- walking speed -- arm circumference
Geriatrics -- Periodicals
618.97 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0002-8614) ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-5415 ↗
http://www.blackwell-synergy.com/Journals/issuelist.asp?journal=jgs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0002-8614;screen=info;ECOIP ↗ - DOI:
- 10.1111/jgs.15204 ↗
- Languages:
- English
- ISSNs:
- 0002-8614
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4686.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22299.xml