Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study. Issue 1 (10th September 2019)
- Record Type:
- Journal Article
- Title:
- Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study. Issue 1 (10th September 2019)
- Main Title:
- Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study
- Authors:
- Trivelato, Felipe Padovani
Wajnberg, Eduardo
Rezende, Marco Túlio Salles
Ulhôa, Alexandre Cordeiro
Piske, Ronie Leo
Abud, Thiago Giansante
de Castro-Afonso, Luís Henrique
Abath, Carlos Gustavo Coutinho
Nakiri, Guilherme Seizem
Araújo, João Francisco Santoro
Silva, José Laércio Júnior
Tosello, Renato Tavares
Vanzin, José Ricardo
Manzato, Luciano Bambini
Baccin, Carlos Eduardo
da Mota, Bruno Anderson Araújo
Abud, Daniel Giansante - Abstract:
- Abstract: BACKGROUND: The safety and efficacy of the first generation of the Pipeline Embolization Device (PED; Medtronic Inc) have been proven in large case series. Ischemic events are one of the most common complications following treatment of aneurysms with flow diverters. The new PED Flex with Shield technology (PED Shield; Medtronic Inc) was introduced to minimize the rate of complications. OBJECTIVE: To evaluate the outcomes of patients harboring aneurysms treated with the PED Shield. METHODS: This was an observational, prospective, single-arm multicenter study of patients treated with the PED Shield. The primary safety endpoint was the absence of major neurological complications and death. The secondary effectiveness endpoint was angiographic occlusion at 6 and 12 mo. Technical complications were also reported. RESULTS: Between November 2017 and December 2018, 151 patients from 7 centers with 182 aneurysms were enrolled. The mean aneurysm size was 7.0 mm; 27 (14.8%) aneurysms were large, and 7 (3.8%) were giant. In 141 of 151 patients (93.4%), the primary endpoint was reached. The overall rate of periprocedural complications was 7.3%. Of the aneurysms, 79.7% met the study's secondary endpoint of complete occlusion at 6 mo and 85.3% at 12 mo. CONCLUSION: The PED Shield is a safe and effective treatment for intracranial aneurysms. The results regarding total occlusion and ischemic complications did not differ from those obtained in case series using previous versions ofAbstract: BACKGROUND: The safety and efficacy of the first generation of the Pipeline Embolization Device (PED; Medtronic Inc) have been proven in large case series. Ischemic events are one of the most common complications following treatment of aneurysms with flow diverters. The new PED Flex with Shield technology (PED Shield; Medtronic Inc) was introduced to minimize the rate of complications. OBJECTIVE: To evaluate the outcomes of patients harboring aneurysms treated with the PED Shield. METHODS: This was an observational, prospective, single-arm multicenter study of patients treated with the PED Shield. The primary safety endpoint was the absence of major neurological complications and death. The secondary effectiveness endpoint was angiographic occlusion at 6 and 12 mo. Technical complications were also reported. RESULTS: Between November 2017 and December 2018, 151 patients from 7 centers with 182 aneurysms were enrolled. The mean aneurysm size was 7.0 mm; 27 (14.8%) aneurysms were large, and 7 (3.8%) were giant. In 141 of 151 patients (93.4%), the primary endpoint was reached. The overall rate of periprocedural complications was 7.3%. Of the aneurysms, 79.7% met the study's secondary endpoint of complete occlusion at 6 mo and 85.3% at 12 mo. CONCLUSION: The PED Shield is a safe and effective treatment for intracranial aneurysms. The results regarding total occlusion and ischemic complications did not differ from those obtained in case series using previous versions of the PED. Long-term follow-up and comparative studies are required to provide stronger conclusions regarding the reduced thrombogenicity of this device. … (more)
- Is Part Of:
- Neurosurgery. Volume 87:Issue 1(2020)
- Journal:
- Neurosurgery
- Issue:
- Volume 87:Issue 1(2020)
- Issue Display:
- Volume 87, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 87
- Issue:
- 1
- Issue Sort Value:
- 2020-0087-0001-0000
- Page Start:
- 104
- Page End:
- 111
- Publication Date:
- 2019-09-10
- Subjects:
- Aneurysm -- Embolization -- Endovascular -- Flow diverter
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyz356 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22297.xml