Investigation the influence of structure parameters on giant-magnetoimpedance effect measured by non-contact method. Issue 6 (11th October 2020)
- Record Type:
- Journal Article
- Title:
- Investigation the influence of structure parameters on giant-magnetoimpedance effect measured by non-contact method. Issue 6 (11th October 2020)
- Main Title:
- Investigation the influence of structure parameters on giant-magnetoimpedance effect measured by non-contact method
- Authors:
- Feng, Zhu
Zhi, Shaotao
Sun, Xuecheng
Yan, Lili
Liu, Cui
Lei, Chong - Abstract:
- Abstract : Purpose: This paper aims to investigate the influence of structure parameters on giant-magnetoimpedance (GMI) effect measured by non-contact method. Design/methodology/approach: The GMI sensor contains a Co-based internal magnetic core fabricated by laser cutting and an external solenoid. The influences of magnetic permeability of magnetic core and structure parameters on GMI effect were calculated in theoretical model. The output impedance, resistance, reactance and GMI ratio were measured by non-contact method using impedance analyzer. Findings: Enhancing external magnetic field intensity can decrease the magnetic permeability of core, which has vital influences on the magnetic property and the output response of GMI sensor. In addition, increasing the width of magnetic core and the number of solenoid turns can increase the maximum GMI ratio. The maximum GMI ratio is 3, 230% with core width of 6 mm and solenoid turns of 200. Originality/value: Comparing with traditional contact-measured GMI sensor, the maximum GMI ratio and the magnetic field sensitivity are improved and the power consumption is decreased in non-contact measured GMI sensor. GMI sensor measured by non-contact method has a wide range of potential applications in ultra-sensitive magnetic field detection.
- Is Part Of:
- Sensor review. Volume 40:Issue 6(2020)
- Journal:
- Sensor review
- Issue:
- Volume 40:Issue 6(2020)
- Issue Display:
- Volume 40, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 40
- Issue:
- 6
- Issue Sort Value:
- 2020-0040-0006-0000
- Page Start:
- 647
- Page End:
- 656
- Publication Date:
- 2020-10-11
- Subjects:
- Giant-magnetoimpedance -- Non-contact method -- Magnetic sensor -- Laser cutting -- Structure parameter
Sensor systems -- Periodicals
Detectors -- Industrial applications -- Periodicals
Engineering instruments -- Periodicals
681.2 - Journal URLs:
- http://www.emeraldinsight.com/journals.htm?issn=0260-2288 ↗
http://www.emeraldinsight.com/ ↗ - DOI:
- 10.1108/SR-07-2019-0169 ↗
- Languages:
- English
- ISSNs:
- 0260-2288
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8241.782000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22297.xml