Air curtains for reduction of natural convection heat loss from a heated plate: A numerical investigation. (15th June 2022)
- Record Type:
- Journal Article
- Title:
- Air curtains for reduction of natural convection heat loss from a heated plate: A numerical investigation. (15th June 2022)
- Main Title:
- Air curtains for reduction of natural convection heat loss from a heated plate: A numerical investigation
- Authors:
- Mondal, Razon
Torres, Juan F.
Hughes, Graham
Pye, John - Abstract:
- Highlights: A downward air jet is used to suppress natural convection from a near-vertical wall. The jet lowers convective heat loss by ∼ 30% at the top of the wall, near the jet. There is a ∼ 20% reduction in heat loss in the laminar-turbulent transition zone. The concept could be applied to reduce heat loss from solar-thermal receivers. Abstract: Concentrating solar power (CSP) plants encounter inefficiencies at all stages of electricity generation. Convection from the solar-thermal receiver is a significant mode of heat loss in CSP systems, and is challenging to mitigate. This study investigates the reduction of convection losses by using a planar jet that disrupts the buoyant flow arising from the heated surface of an external CSP receiver. An isothermal flat plate with a height of 1.8 m was used to model the receiver, and a planar jet air curtain with a nozzle thickness of 3 mm was introduced near the upper edge of the wall. A computational fluid dynamics model was first validated and subsequently implemented to conduct a parametric study on the heat transfer from the isothermal plate with an air curtain varying four parameters: jet speed, jet angle, plate temperature and plate inclination. The results showed that the air curtain generates a stagnation zone adjacent to the wall which successfully reduces local convective heat losses. The effectiveness of an air curtain is defined here as the relative reduction in the local heat loss due to the air curtain, compared toHighlights: A downward air jet is used to suppress natural convection from a near-vertical wall. The jet lowers convective heat loss by ∼ 30% at the top of the wall, near the jet. There is a ∼ 20% reduction in heat loss in the laminar-turbulent transition zone. The concept could be applied to reduce heat loss from solar-thermal receivers. Abstract: Concentrating solar power (CSP) plants encounter inefficiencies at all stages of electricity generation. Convection from the solar-thermal receiver is a significant mode of heat loss in CSP systems, and is challenging to mitigate. This study investigates the reduction of convection losses by using a planar jet that disrupts the buoyant flow arising from the heated surface of an external CSP receiver. An isothermal flat plate with a height of 1.8 m was used to model the receiver, and a planar jet air curtain with a nozzle thickness of 3 mm was introduced near the upper edge of the wall. A computational fluid dynamics model was first validated and subsequently implemented to conduct a parametric study on the heat transfer from the isothermal plate with an air curtain varying four parameters: jet speed, jet angle, plate temperature and plate inclination. The results showed that the air curtain generates a stagnation zone adjacent to the wall which successfully reduces local convective heat losses. The effectiveness of an air curtain is defined here as the relative reduction in the local heat loss due to the air curtain, compared to the case of natural convection alone. A local maximum of 31.2% effectiveness is achieved in the stagnation zone below the jet outlet for a vertical wall with a jet speed of 2.5 ms − 1 and jet angle of 45 ∘ . The air curtain effectiveness at the stagnation region was found to decrease with increasing jet speeds, whereas the effectiveness increased near the laminar-to-turbulent transition region with increasing jet speed. Smaller air curtain angles relative to the wall resulted in lower effectiveness. A 45 ∘ air curtain on a vertical wall can offer performance benefits that are similar in magnitude to inclining a wall from the vertical. A higher wall temperature was accompanied by better effectiveness near the jet outlet, particularly in the stagnation region, while lower wall temperatures produced higher effectiveness further from the jet. Therefore, an air curtain can be used to reduce convective heat losses locally from a heated flat surface, including potentially when applied to CSP receivers. … (more)
- Is Part Of:
- International journal of heat and mass transfer. Volume 189(2022)
- Journal:
- International journal of heat and mass transfer
- Issue:
- Volume 189(2022)
- Issue Display:
- Volume 189, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 189
- Issue:
- 2022
- Issue Sort Value:
- 2022-0189-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-15
- Subjects:
- External solar-thermal receiver -- Natural convection -- Air curtain effectiveness -- Convective heat loss
Heat -- Transmission -- Periodicals
Mass transfer -- Periodicals
Chaleur -- Transmission -- Périodiques
Transfert de masse -- Périodiques
Electronic journals
621.4022 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00179310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijheatmasstransfer.2022.122709 ↗
- Languages:
- English
- ISSNs:
- 0017-9310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.280000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22281.xml