A framework for the design of a closed-loop gastric pacemaker for treating conduction block. (April 2022)
- Record Type:
- Journal Article
- Title:
- A framework for the design of a closed-loop gastric pacemaker for treating conduction block. (April 2022)
- Main Title:
- A framework for the design of a closed-loop gastric pacemaker for treating conduction block
- Authors:
- Wang, Luman
Malik, Avinash
Roop, Partha S.
Cheng, Leo K.
Paskaranandavadivel, Niranchan - Abstract:
- Highlights: Closed-loop Gastric Electrical Stimulators (GES) are essential for treating gastrointestinal dysrhythmias, and a practical closed-loop GES will sense and process extracellular potentials. Extracellular potentials that emulate experimental recordings are generated by the proposed extracellular generation model. The proposed closed-loop GES model has the ability to sense and process the extracellular potentials, and effectively modulate a variety of bradygastric patterns, including conduction block. Abstract: Background and Objective: Gastrointestinal (GI) motility disorders can be significantly detrimental to the quality of life. Pacing, or long pulse gastric electrical stimulation, is a potential treatment option for treating GI motility disorders by modulating the slow wave activity. Open-loop pacing of the GI tract is the current standard for modulating dysrhythmic patterns, but it is known to be suboptimal and inefficient. Recent work on sensing intracellular potentials and pacing accordingly in a closed-loop has been shown to be effective at modulating dysrhythmic patterns. However, capturing intracellular potentials in an in-vivo setting is not viable. Therefore a closed-loop gastric electrical stimulation that can sense extracellular potentials and pace accordingly to modulate dysrhythmic patterns is required. This paper presents a closed-loop Gastric Electrical Stimulator (GES) design framework, which comprises of extracellular potential generation,Highlights: Closed-loop Gastric Electrical Stimulators (GES) are essential for treating gastrointestinal dysrhythmias, and a practical closed-loop GES will sense and process extracellular potentials. Extracellular potentials that emulate experimental recordings are generated by the proposed extracellular generation model. The proposed closed-loop GES model has the ability to sense and process the extracellular potentials, and effectively modulate a variety of bradygastric patterns, including conduction block. Abstract: Background and Objective: Gastrointestinal (GI) motility disorders can be significantly detrimental to the quality of life. Pacing, or long pulse gastric electrical stimulation, is a potential treatment option for treating GI motility disorders by modulating the slow wave activity. Open-loop pacing of the GI tract is the current standard for modulating dysrhythmic patterns, but it is known to be suboptimal and inefficient. Recent work on sensing intracellular potentials and pacing accordingly in a closed-loop has been shown to be effective at modulating dysrhythmic patterns. However, capturing intracellular potentials in an in-vivo setting is not viable. Therefore a closed-loop gastric electrical stimulation that can sense extracellular potentials and pace accordingly to modulate dysrhythmic patterns is required. This paper presents a closed-loop Gastric Electrical Stimulator (GES) design framework, which comprises of extracellular potential generation, sensing, and closed-loop actuation. Methods: This work leverages a pre-existing high-fidelity two-dimensional Interstitial Cells of Cajal (ICC) network modeling framework to mimic several normal and dysrhythmic patterns observed in experimental recordings of patients suffering from GI tract diseases. The activation patterns of the of the ICC network are captured by an extracellular potential generation model and is integrated with the GES in a closed-loop to validate the efficacy of the developed pacing algorithms. The proposed GES pacing algorithms extend existing offline filtering and activation detection methods to process the sensed extracellular potentials in real time. The GES detects bradygastric rhythms based on the sensed extracellular potentials and actuates the ICC network via pacing to rectify dysrhythmic patterns. Results: The proposed GES model is able to sense and process the generated noisy extracellular potentials, detect the bradygastric patterns, and modulate the slow wave activities to normal propagation effectively. Conclusions: A closed-loop GES design, which can be applied in an experimental and clinical setting is developed and validated through the ICC network model. The proposed GES model has the ability to modulate a variety of bradygastric patterns, including conduction block effectively in a closed-loop. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 216(2022)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 216(2022)
- Issue Display:
- Volume 216, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 216
- Issue:
- 2022
- Issue Sort Value:
- 2022-0216-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-04
- Subjects:
- Gastric electrical stimulator (GES) -- Closed-loop design -- Gastrointestinal tract modeling -- Extracellular potential generation -- Device validation
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.106652 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22281.xml