VP-Detector: A 3D multi-scale dense convolutional neural network for macromolecule localization and classification in cryo-electron tomograms. (June 2022)
- Record Type:
- Journal Article
- Title:
- VP-Detector: A 3D multi-scale dense convolutional neural network for macromolecule localization and classification in cryo-electron tomograms. (June 2022)
- Main Title:
- VP-Detector: A 3D multi-scale dense convolutional neural network for macromolecule localization and classification in cryo-electron tomograms
- Authors:
- Hao, Yu
Wan, Xiaohua
Yan, Rui
Liu, Zhiyong
Li, Jintao
Zhang, Shihua
Cui, Xuefeng
Zhang, Fa - Abstract:
- Abstract: Background and objective: Cryo-electron tomography (cryo-ET) with subtomogram averaging (STA) is indispensable when studying macromolecule structures and functions in their native environments. Due to the low signal-to-noise ratio, the missing wedge artifacts in tomographic reconstructions, and multiple macromolecules of varied shapes and sizes, macromolecule localization and classification remain challenging. To tackle this bottleneck problem for structural determination by STA, we design an accurate macromolecule localization and classification method named voxelwise particle detector (VP-Detector). Methods: VP-Detector is a two-stage particle detection method based on a 3D multiscale dense convolutional neural network (3D MSDNet). The proposed network uses 3D hybrid dilated convolution (3D HDC) to avoid the resolution loss caused by scaling operations. Meanwhile, it uses 3D dense connectivity to encourage the reuse of feature maps to reduce trainable parameters. In addition, the weighted focal loss is proposed to focus more attention on difficult samples and rare classes, which relieves the class imbalance caused by multiple particles of various sizes. The performance of VP-Detector is evaluated on both simulated and real-world tomograms, and it shows that VP-Detector outperforms state-of-the-art methods. Results: The experiments show that VP-Detector outperforms the state-of-the-art methods on particle localization with an F1-score of 0.951 and a precision ofAbstract: Background and objective: Cryo-electron tomography (cryo-ET) with subtomogram averaging (STA) is indispensable when studying macromolecule structures and functions in their native environments. Due to the low signal-to-noise ratio, the missing wedge artifacts in tomographic reconstructions, and multiple macromolecules of varied shapes and sizes, macromolecule localization and classification remain challenging. To tackle this bottleneck problem for structural determination by STA, we design an accurate macromolecule localization and classification method named voxelwise particle detector (VP-Detector). Methods: VP-Detector is a two-stage particle detection method based on a 3D multiscale dense convolutional neural network (3D MSDNet). The proposed network uses 3D hybrid dilated convolution (3D HDC) to avoid the resolution loss caused by scaling operations. Meanwhile, it uses 3D dense connectivity to encourage the reuse of feature maps to reduce trainable parameters. In addition, the weighted focal loss is proposed to focus more attention on difficult samples and rare classes, which relieves the class imbalance caused by multiple particles of various sizes. The performance of VP-Detector is evaluated on both simulated and real-world tomograms, and it shows that VP-Detector outperforms state-of-the-art methods. Results: The experiments show that VP-Detector outperforms the state-of-the-art methods on particle localization with an F1-score of 0.951 and a precision of 0.978. In addition, VP-Detector can replace manual particle picking in experiment on the real-world tomograms. Furthermore, it performs well in classifying large-, medium-, and small-weight proteins with accuracies of 1, 0.95, and 0.82, respectively. Finally, ablation studies demonstrate the effectiveness of 3D HDC, 3D dense connectivity, weighted focal loss, and training on small training sets. Conclusions: VP-Detector can achieve high accuracy in particle detection with few trainable parameters and support training on small datasets. It can also relieve the class imbalance caused by multiple particles with various shapes and sizes. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 221(2022)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 221(2022)
- Issue Display:
- Volume 221, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 221
- Issue:
- 2022
- Issue Sort Value:
- 2022-0221-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Cryo-ET -- Sub-tomogram averaging -- Particle localization -- Particle classification -- Convolutional neural networks
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.106871 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22255.xml