Evaluation of the long‐term results of vascular anastomosis using polyurethane adhesive and shape‐memory stent in the rat carotid artery model. Issue 5 (7th June 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of the long‐term results of vascular anastomosis using polyurethane adhesive and shape‐memory stent in the rat carotid artery model. Issue 5 (7th June 2022)
- Main Title:
- Evaluation of the long‐term results of vascular anastomosis using polyurethane adhesive and shape‐memory stent in the rat carotid artery model
- Authors:
- Heitzer, Marius
Ooms, Mark
Katz, Marie Sophie
Peters, Florian
Kilic, Konrad
Tolba, René
Jockenhoevel, Stefan
Hermanns‐Sachweh, Benita
Hölzle, Frank
Modabber, Ali - Abstract:
- Abstract: Introduction: In free flaps, 5%–10% of complications are related to failure of sutured vascular anastomoses. Adhesive‐based microvascular anastomoses are potential alternatives but are associated with failure rates of 70% in research studies. VIVO is a new adhesive with slow biodegradation within 6 months that has shown a 100% patency rate in research studies over 2 h observation time but long‐term patency has not been evaluated. The authors hypothesize that VIVO will enable a reliable microvascular procedure comparable to sutured anastomoses over a 28‐day period. Materials and Methods: The right common carotid artery of 60 male Sprague Dawley rats, ~450 g, were used for microvascular end‐to‐end anastomosis. VIVO was applied with reduced sutures with a temporary catheter in one group and in the other with a custom‐shaped memory stent. Anastomoses with eight interrupted sutures served as control. All groups were n = 20. Anastomosis time and bleeding were recorded for each procedure. Doppler flowmetry was performed 20 min, 1, 10, and 28 days postoperatively. Postmortem toluidine staining was used for semi‐quantitative analysis of stenosis, thrombosis, necrosis, and aneurysm formation by histologic evaluation. Results: No occlusion was detected 20 min and 1 day postoperative, and after 28 days of observation in all anastomoses. The anastomosis time of the VIVO with catheter group was about 32% significantly faster than the VIVO with stent group. In the VIVO groupAbstract: Introduction: In free flaps, 5%–10% of complications are related to failure of sutured vascular anastomoses. Adhesive‐based microvascular anastomoses are potential alternatives but are associated with failure rates of 70% in research studies. VIVO is a new adhesive with slow biodegradation within 6 months that has shown a 100% patency rate in research studies over 2 h observation time but long‐term patency has not been evaluated. The authors hypothesize that VIVO will enable a reliable microvascular procedure comparable to sutured anastomoses over a 28‐day period. Materials and Methods: The right common carotid artery of 60 male Sprague Dawley rats, ~450 g, were used for microvascular end‐to‐end anastomosis. VIVO was applied with reduced sutures with a temporary catheter in one group and in the other with a custom‐shaped memory stent. Anastomoses with eight interrupted sutures served as control. All groups were n = 20. Anastomosis time and bleeding were recorded for each procedure. Doppler flowmetry was performed 20 min, 1, 10, and 28 days postoperatively. Postmortem toluidine staining was used for semi‐quantitative analysis of stenosis, thrombosis, necrosis, and aneurysm formation by histologic evaluation. Results: No occlusion was detected 20 min and 1 day postoperative, and after 28 days of observation in all anastomoses. The anastomosis time of the VIVO with catheter group was about 32% significantly faster than the VIVO with stent group. In the VIVO group with stent, the bleeding time was ~80% shorter than in the control group with 2.1 ± 0.3 and VIVO with catheter 2.0 ± 0.5 ( p ≤ .001 each). Minor and nonsignificant stent‐associated thrombus formation and stent‐typical intraluminal stenosis were detected exclusively in the VIVO with stent group. Conclusion: Within the limitations of a rat study, the use of VIVO in anastomosis showed promising results. VIVO with catheter was found to be advantageous. … (more)
- Is Part Of:
- Microsurgery. Volume 42:Issue 5(2022)
- Journal:
- Microsurgery
- Issue:
- Volume 42:Issue 5(2022)
- Issue Display:
- Volume 42, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2022-0042-0005-0000
- Page Start:
- 480
- Page End:
- 489
- Publication Date:
- 2022-06-07
- Subjects:
- Microsurgery -- Periodicals
617.05 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2752 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/micr.30926 ↗
- Languages:
- English
- ISSNs:
- 0738-1085
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.770000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22257.xml