Experimental study on the spray cooling heat transfer performance and dimensionless correlations for ethylene glycol water solution. (September 2022)
- Record Type:
- Journal Article
- Title:
- Experimental study on the spray cooling heat transfer performance and dimensionless correlations for ethylene glycol water solution. (September 2022)
- Main Title:
- Experimental study on the spray cooling heat transfer performance and dimensionless correlations for ethylene glycol water solution
- Authors:
- Zhou, Nianyong
Feng, Hao
Guo, Yixing
Chen, Haifei
Liu, Wenbo
Peng, Haoping
Lei, Yun
Deng, Song
Xu, Yu - Abstract:
- Highlights: A wider range of temperature and mass fraction with Ethylene Glycol solution is. studied for spray cooling. Heat transfer performance will deteriorate rapidly with the rise of Ethylene. Glycol mass fraction. The main factors of inlet temperature on heat transfer are Weber number and. Evaporation intensity. A new Nusselt number dimensionless correlation of ethylene glycol is proposed within the 10 % error. Abstract: With the increase of airborne electronic equipment heat dissipation, spray cooling with ethylene glycol as working fluid may be an effective way. In this paper, the influence of ethylene glycol mass fraction, mass flow rate, and nozzle inlet temperature on the spray cooling heat transfer performance are experimentally studied. Results show that the ethylene glycol mass fraction significantly affects the heat transfer performance. When the mass fraction increases from 0 to 100%, the maximum reduction of surface heat transfer coefficient is about to 58% at different heat flux. The increase of dynamic viscosity and the decrease of specific heat capacity and thermal conductivity are the direct cause, which significantly weaken heat transfer performance. As the nozzle inlet temperature rises from –2 to 50℃, the surface heat transfer coefficient increases gradually and tends to be stable. The evaporation intensity has the same trend with inlet temperature, and also evaporation is a non-negligible heat transfer form in spray cooling. In addition, a moreHighlights: A wider range of temperature and mass fraction with Ethylene Glycol solution is. studied for spray cooling. Heat transfer performance will deteriorate rapidly with the rise of Ethylene. Glycol mass fraction. The main factors of inlet temperature on heat transfer are Weber number and. Evaporation intensity. A new Nusselt number dimensionless correlation of ethylene glycol is proposed within the 10 % error. Abstract: With the increase of airborne electronic equipment heat dissipation, spray cooling with ethylene glycol as working fluid may be an effective way. In this paper, the influence of ethylene glycol mass fraction, mass flow rate, and nozzle inlet temperature on the spray cooling heat transfer performance are experimentally studied. Results show that the ethylene glycol mass fraction significantly affects the heat transfer performance. When the mass fraction increases from 0 to 100%, the maximum reduction of surface heat transfer coefficient is about to 58% at different heat flux. The increase of dynamic viscosity and the decrease of specific heat capacity and thermal conductivity are the direct cause, which significantly weaken heat transfer performance. As the nozzle inlet temperature rises from –2 to 50℃, the surface heat transfer coefficient increases gradually and tends to be stable. The evaporation intensity has the same trend with inlet temperature, and also evaporation is a non-negligible heat transfer form in spray cooling. In addition, a more widely applicable Nusselt number dimensionless correlation of ethylene glycol solution is proposed within the 10% error. The investigation in wider range of temperature and mass fraction will provide theoretical analysis and data support for the airborne application of spray cooling. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 214(2022)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 214(2022)
- Issue Display:
- Volume 214, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 214
- Issue:
- 2022
- Issue Sort Value:
- 2022-0214-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- Spray cooling -- Ethylene glycol water solution -- Influencing factors -- Dimensionless correlations
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2022.118824 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22258.xml