THE EFFECTS OF CONE-BEAM COMPUTED TOMOGRAPHY IMAGING GUIDANCE ON PATIENT RADIATION EXPOSURES IN TRANS-ARTERIAL CHEMOEMBOLISATION FOR HEPATOCELLULAR CARCINOMA. Issue 8 (30th May 2022)
- Record Type:
- Journal Article
- Title:
- THE EFFECTS OF CONE-BEAM COMPUTED TOMOGRAPHY IMAGING GUIDANCE ON PATIENT RADIATION EXPOSURES IN TRANS-ARTERIAL CHEMOEMBOLISATION FOR HEPATOCELLULAR CARCINOMA. Issue 8 (30th May 2022)
- Main Title:
- THE EFFECTS OF CONE-BEAM COMPUTED TOMOGRAPHY IMAGING GUIDANCE ON PATIENT RADIATION EXPOSURES IN TRANS-ARTERIAL CHEMOEMBOLISATION FOR HEPATOCELLULAR CARCINOMA
- Authors:
- Wong, S Y
Foley, S
Cantwell, C P
Ryan, R
Lucey, J
Maher, P
McNulty, J P - Abstract:
- Abstract: This study investigated the effects of cone-beam computed tomography (CBCT) guidance in trans-arterial chemoembolisation (TACE) procedures on the number of digital subtraction angiography (DSA) runs acquired and total patient radiation exposure in patients with hepatocellular carcinoma (HCC). A retrospective, analytical cross-sectional, single institution, study was conducted. Dose data were compared across the control (DSA guidance alone) and study (DSA and CBCT guidance) groups. A total of 122 procedures were included within the study. There was a significant reduction in the number of DSA runs (3 vs 5, p < 0.001 ) and DSA air kerma-area product (PKA) (3077.3 vs 4276.6 μGym 2, p = 0.042 ) for the study group when compared to the control group. Total procedural PKA and total procedural reference air kerma (Ka, r ) were shown to be 50 and 73% higher, respectively, for the study group when compared to the control group. CBCT imaging guidance does reduce the number of DSA runs and DSA PKA required to complete the TACE procedure for patients diagnosed with HCC; however, a substantial increase in total procedural PKA is to be expected and it is thus important that this increased dose is carefully considered and justified.
- Is Part Of:
- Radiation protection dosimetry. Volume 198:Issue 8(2022)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 198:Issue 8(2022)
- Issue Display:
- Volume 198, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 198
- Issue:
- 8
- Issue Sort Value:
- 2022-0198-0008-0000
- Page Start:
- 441
- Page End:
- 447
- Publication Date:
- 2022-05-30
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncac077 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22271.xml