Direct measurement of oxygen reduction reactions at neurostimulation electrodes. (1st June 2022)
- Record Type:
- Journal Article
- Title:
- Direct measurement of oxygen reduction reactions at neurostimulation electrodes. (1st June 2022)
- Main Title:
- Direct measurement of oxygen reduction reactions at neurostimulation electrodes
- Authors:
- Ehlich, Jiří
Migliaccio, Ludovico
Sahalianov, Ihor
Nikić, Marta
Brodský, Jan
Gablech, Imrich
Vu, Xuan Thang
Ingebrandt, Sven
Głowacki, Eric Daniel - Abstract:
- Abstract: Objective . Electric stimulation delivered by implantable electrodes is a key component of neural engineering. While factors affecting long-term stability, safety, and biocompatibility are a topic of continuous investigation, a widely-accepted principle is that charge injection should be reversible, with no net electrochemical products forming. We want to evaluate oxygen reduction reactions (ORR) occurring at different electrode materials when using established materials and stimulation protocols. Approach . As stimulation electrodes, we have tested platinum, gold, tungsten, nichrome, iridium oxide, titanium, titanium nitride, and poly(3, 4-ethylenedioxythiophene):poly(styrene sulfonate). We use cyclic voltammetry and voltage-step amperometry in oxygenated versus inert conditions to establish at which potentials ORR occurs, and the magnitudes of diffusion-limited ORR currents. We also benchmark the areal capacitance of each electrode material. We use amperometric probes (Clark-type electrodes) to quantify the O2 and H2 O2 concentrations in the vicinity of the electrode surface. O2 and H2 O2 concentrations are measured while applying DC current, or various biphasic charge-balanced pulses of amplitude in the range 10–30 µ C cm −2 /phase. To corroborate experimental measurements, we employ finite element modelling to recreate 3D gradients of O2 and H2 O2 . Main results . All electrode materials support ORR and can create hypoxic conditions near the electrode surface.Abstract: Objective . Electric stimulation delivered by implantable electrodes is a key component of neural engineering. While factors affecting long-term stability, safety, and biocompatibility are a topic of continuous investigation, a widely-accepted principle is that charge injection should be reversible, with no net electrochemical products forming. We want to evaluate oxygen reduction reactions (ORR) occurring at different electrode materials when using established materials and stimulation protocols. Approach . As stimulation electrodes, we have tested platinum, gold, tungsten, nichrome, iridium oxide, titanium, titanium nitride, and poly(3, 4-ethylenedioxythiophene):poly(styrene sulfonate). We use cyclic voltammetry and voltage-step amperometry in oxygenated versus inert conditions to establish at which potentials ORR occurs, and the magnitudes of diffusion-limited ORR currents. We also benchmark the areal capacitance of each electrode material. We use amperometric probes (Clark-type electrodes) to quantify the O2 and H2 O2 concentrations in the vicinity of the electrode surface. O2 and H2 O2 concentrations are measured while applying DC current, or various biphasic charge-balanced pulses of amplitude in the range 10–30 µ C cm −2 /phase. To corroborate experimental measurements, we employ finite element modelling to recreate 3D gradients of O2 and H2 O2 . Main results . All electrode materials support ORR and can create hypoxic conditions near the electrode surface. We find that electrode materials differ significantly in their onset potentials for ORR, and in the extent to which they produce H2 O2 as a by-product. A key result is that typical charge-balanced biphasic pulse protocols do lead to irreversible ORR. Some electrodes induce severely hypoxic conditions, others additionally produce an accumulation of hydrogen peroxide into the mM range. Significance . Our findings highlight faradaic ORR as a critical consideration for neural interface devices and show that the established biphasic/charge-balanced approach does not prevent irreversible changes in O2 concentrations. Hypoxia and H2 O2 can result in different (electro)physiological consequences. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 19:Number 3(2022)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 19:Number 3(2022)
- Issue Display:
- Volume 19, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 19
- Issue:
- 3
- Issue Sort Value:
- 2022-0019-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-01
- Subjects:
- bioelectronics -- neurostimulation -- faradaic reactions -- hypoxia -- reactive oxygen species
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2552/ac77c0 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22243.xml