An HFman probe-based reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for HIV-1 detection. (August 2022)
- Record Type:
- Journal Article
- Title:
- An HFman probe-based reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for HIV-1 detection. (August 2022)
- Main Title:
- An HFman probe-based reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for HIV-1 detection
- Authors:
- Zhang, Xiaoling
Li, Hanping
Liu, Ziwei
Zhao, Yongjuan
Zeng, Yi
Dong, Yajuan
Li, Lin
Zhang, Chiyu - Abstract:
- Abstract: Loop-mediated isothermal amplification (LAMP) is suitable for the development of a rapid and cost-effective nucleic acid technique for point of care (POC) applications. However, LAMP methods often generate non-specific amplification, therefore inevitably resulting in false positive results especially when sequence-independent dyes are used to indirectly reflect the results. In this study, we established and optimized a reverse transcription LAMP (RT-LAMP) assay with a high-fidelity DNA polymerase-mediated fluorescent probe (HFman probe) for human immunodeficiency virus-1 (HIV-1) detection. The assay showed high sensitivity and specificity. Using 101 plasma samples with different HIV-1 viral load, we demonstrated that our assay can detect the major HIV-1 subtypes circulating in China, including CRF01_AE, CRF07_BC, CRF08_BC, CRF55_01B, and unique recombinant forms (URFs). We also compared our assay with an approved commercial real-time quantitative polymerase chain reaction (RT-qPCR) kit and found the sensitivity, specificity and consistency was 88.8%, 100% and 89.1%, respectively. The HFman probe-based RT-LAMP assay is a high specific detection method that is rapid, variant-tolerant and simple to operate, and thus is of great significance for timely disclosure of HIV status and rapid POC diagnosis. Graphical abstract: Image 1 Highlights: An HFman probe-based RT-LAMP assay was developed for specific detection of HIV-1. The assay is rapid, variant-tolerant, sensitiveAbstract: Loop-mediated isothermal amplification (LAMP) is suitable for the development of a rapid and cost-effective nucleic acid technique for point of care (POC) applications. However, LAMP methods often generate non-specific amplification, therefore inevitably resulting in false positive results especially when sequence-independent dyes are used to indirectly reflect the results. In this study, we established and optimized a reverse transcription LAMP (RT-LAMP) assay with a high-fidelity DNA polymerase-mediated fluorescent probe (HFman probe) for human immunodeficiency virus-1 (HIV-1) detection. The assay showed high sensitivity and specificity. Using 101 plasma samples with different HIV-1 viral load, we demonstrated that our assay can detect the major HIV-1 subtypes circulating in China, including CRF01_AE, CRF07_BC, CRF08_BC, CRF55_01B, and unique recombinant forms (URFs). We also compared our assay with an approved commercial real-time quantitative polymerase chain reaction (RT-qPCR) kit and found the sensitivity, specificity and consistency was 88.8%, 100% and 89.1%, respectively. The HFman probe-based RT-LAMP assay is a high specific detection method that is rapid, variant-tolerant and simple to operate, and thus is of great significance for timely disclosure of HIV status and rapid POC diagnosis. Graphical abstract: Image 1 Highlights: An HFman probe-based RT-LAMP assay was developed for specific detection of HIV-1. The assay is rapid, variant-tolerant, sensitive and specific. The assay can detect various HIV-1 subtypes and recombinants circulating in China. Clinical evaluation showed a well consistency between the novel RT-LAMP assay with commercial RT-qPCR kit. … (more)
- Is Part Of:
- Molecular and cellular probes. Volume 64(2022)
- Journal:
- Molecular and cellular probes
- Issue:
- Volume 64(2022)
- Issue Display:
- Volume 64, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 64
- Issue:
- 2022
- Issue Sort Value:
- 2022-0064-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-08
- Subjects:
- RT-LAMP -- Specificity -- HFman probe -- HIV-1 -- Subtype -- Viral load
Molecular probes -- Diagnostic use -- Periodicals
Pathology, Cellular -- Technique -- Periodicals
Cell Biology -- Periodicals
Molecular Biology -- Periodicals
Sondes moléculaires -- Utilisation diagnostique -- Périodiques
Cytopathologie -- Technique -- Périodiques
572 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08908508 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0890-8508;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.mcp.2022.101834 ↗
- Languages:
- English
- ISSNs:
- 0890-8508
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5900.761000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: