MO607: Intradialytic Exercise: A Large-Scale Nationwide Implementation Study. (3rd May 2022)
- Record Type:
- Journal Article
- Title:
- MO607: Intradialytic Exercise: A Large-Scale Nationwide Implementation Study. (3rd May 2022)
- Main Title:
- MO607: Intradialytic Exercise: A Large-Scale Nationwide Implementation Study
- Authors:
- Martins, Pedro
Vaz Leal, Diogo
Anibal A Ferreira, Manuel
Wilund, Kenneth
Viana, João - Abstract:
- Abstract: BACKGROUND AND AIMS: Intradialytic exercise (IDE) is recommended for HD patients. However, this recommendation is mostly based on research conducted under optimal instead of real-world conditions, limiting generalizability and its implementation into routine clinical care. This study aims to analyze implementation outcomes of IDE in real-world conditions at a large-scale, nationwide level. METHOD: After a pilot experience in a single unit, all NephroCare Portugal dialysis clinics were invited to initiate an IDE program. A national coordinator was nominated, and a nurse and a doctor were selected in each unit as local coordinators. A simple exercise protocol was designed to be easily applied by current dialysis staff (though some units benefited from exercise science student internships). The IDE protocol includes a bout of aerobic exercise (cycle ergometer) and lower limb resistance exercises (ankle weights). The RE-AIM (reach, effectiveness, adoption, implementation and maintenance) framework was used to study clinical implementation over the first year. For each RE-AIM dimension, specific implementation outcomes were adapted to IDE. Effectiveness measures included safety (incidence of intradialytic adverse events over 1 year) and physical function at baseline and at 1 year (sit to stand 30, 8-foot up & go, handgrip strength, sit to stand 5 and single leg stance). For safety measures, IDE group was compared to a group of patients that refused IDE. PhysicalAbstract: BACKGROUND AND AIMS: Intradialytic exercise (IDE) is recommended for HD patients. However, this recommendation is mostly based on research conducted under optimal instead of real-world conditions, limiting generalizability and its implementation into routine clinical care. This study aims to analyze implementation outcomes of IDE in real-world conditions at a large-scale, nationwide level. METHOD: After a pilot experience in a single unit, all NephroCare Portugal dialysis clinics were invited to initiate an IDE program. A national coordinator was nominated, and a nurse and a doctor were selected in each unit as local coordinators. A simple exercise protocol was designed to be easily applied by current dialysis staff (though some units benefited from exercise science student internships). The IDE protocol includes a bout of aerobic exercise (cycle ergometer) and lower limb resistance exercises (ankle weights). The RE-AIM (reach, effectiveness, adoption, implementation and maintenance) framework was used to study clinical implementation over the first year. For each RE-AIM dimension, specific implementation outcomes were adapted to IDE. Effectiveness measures included safety (incidence of intradialytic adverse events over 1 year) and physical function at baseline and at 1 year (sit to stand 30, 8-foot up & go, handgrip strength, sit to stand 5 and single leg stance). For safety measures, IDE group was compared to a group of patients that refused IDE. Physical function measures were only applied to IDE patients, and so comparisons were made between low- and high-frequency exercise groups. RESULTS: Adoption: 21 dialysis units (58.3%). Reach: 1270 eligible patients (55.8%). Main reasons for noneligibility were physical/cognitive incapacity (50.8%) and cardiovascular risk (34.9%). Eligible patients were younger (P < 0.001) and had a better health status (lower comorbidity index: P < 0.001; lower prevalence of diabetes: P < 0.001; lower fat tissue index: P < 0.001; and a higher lean tissue index: P < 0.001). 811 (63.9%) committed to the intervention. Compared with non-IDE patients, IDE patients were younger (<0.001), had a lower dialysis vintage (<0.001), a lower comorbidity index (P < 0.001) and a higher lean tissue index (P = 0.035). Implementation: adherence to exercise sessions was 75.0% ± 19.7%. In 77% of the 50 356 HD treatments, exercise was performed as prescribed. Non-performed exercise sessions ( n = 9768) are mostly justified by patient refusal (61.5%) and pain (8.4%). Patients performed 2.2 ± 0.6 exercise sessions/week achieving 86.3 ± 29.0 min/week. Maintenance (setting level): none of the clinics interrupted IDE. Maintenance (patient level): attrition rate was 57.2% mainly due to voluntary withdrawal (52.4%). Comparing to voluntary withdrawals, completers were mainly males (P < 0.001) and had a lower dialysis vintage (P = 0.007), and higher lean tissue index (P = 0.023). Effectiveness: IDE ( n = 347) and non-IDE patients ( n = 394) were compared. Total incidence of adverse events was lower in IDE, but no significant differences were found (P = 0.808). The individual analysis of each adverse event demonstrated no significant differences for cramps, hypotension, needle dislodgement and other adverse events. Overall physical function improved in IDE (P < 0.001), despite a slight reduction in handgrip strength (P = 0.001). A within-group (low- versus high-frequency exercise) effect was observed, highlighting a deterioration in handgrip strength in the low-frequency group (P = 0.002), whereas no change was observed in the high-frequency group (P = 0.097). CONCLUSION: Large-scale implementation of IDE is a realistic and safe way to promote physical activity in HD patients with benefits on physical function. Yet, to optimize its generalizability, strategies to increase patients´ acceptability and long-term adherence are needed. … (more)
- Is Part Of:
- Nephrology dialysis transplantation. Volume 37(2022)Supplement 3
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 37(2022)Supplement 3
- Issue Display:
- Volume 37, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 3
- Issue Sort Value:
- 2022-0037-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-03
- Subjects:
- Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfac075.020 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22230.xml