Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study. (May 2022)
- Record Type:
- Journal Article
- Title:
- Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study. (May 2022)
- Main Title:
- Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study
- Authors:
- Srinivasan, Murali
Chien, Edward Chaoho
Kalberer, Nicole
Alambiaga Caravaca, Adrian Miguel
Castelleno, Alicia López
Kamnoedboon, Porawit
Sauro, Salvatore
Özcan, Mutlu
Müller, Frauke
Wismeijer, Daniel - Abstract:
- Abstract: Objective: The study aimed to quantitatively evaluate the elution of methylmethacrylate from CAD-CAM manufactured removable complete dentures (RCDs) using high performance liquid chromatography (HPLC). Methods: Thirty-two RCDs were manufactured following either the CNC-milling (Milled: n=8) or the 3D-printing (n=24) protocols. The 3D-printed dentures were further categorized into three groups based on their post-production rinsing cycles [Extended wash cycle (EWC), Standard wash cycle (SWC), and SWC with an additional Durécon coating (SWC2)]. HPLC was used to evaluate the methylmethacrylate concentrations (MMCs) eluted from the dentures in each group for different time periods (1, 2, 4, 8, and 24 hours). Mean and standard deviations were calculated for the MMCs; data was verified for normal distribution, ANOVA and post hoc tests were applied for statistical analyses (⍺=0.05). Results: The HPLC revealed that all the denture groups recorded some amounts of MMCs, with significant differences [F (3, 31) = 23.646, p<0.0001]. The milled denture group had the highest MMCs at 24 hours when compared to the EWC (p<0.0001), SWC (p=0.001), and SWC2 (p<0.0001) denture groups. SWC had a higher MMC than EWC (p=0.032) and SWC2 (p=0.015). No differences were found in MMCs when comparing EWC and SWC2 (p=0.989). Conclusion: Methylmethacrylate concentrations were significantly lower in 3D-printed RCDs than in milled RCDs when using the resins employed in this study. Furthermore, theAbstract: Objective: The study aimed to quantitatively evaluate the elution of methylmethacrylate from CAD-CAM manufactured removable complete dentures (RCDs) using high performance liquid chromatography (HPLC). Methods: Thirty-two RCDs were manufactured following either the CNC-milling (Milled: n=8) or the 3D-printing (n=24) protocols. The 3D-printed dentures were further categorized into three groups based on their post-production rinsing cycles [Extended wash cycle (EWC), Standard wash cycle (SWC), and SWC with an additional Durécon coating (SWC2)]. HPLC was used to evaluate the methylmethacrylate concentrations (MMCs) eluted from the dentures in each group for different time periods (1, 2, 4, 8, and 24 hours). Mean and standard deviations were calculated for the MMCs; data was verified for normal distribution, ANOVA and post hoc tests were applied for statistical analyses (⍺=0.05). Results: The HPLC revealed that all the denture groups recorded some amounts of MMCs, with significant differences [F (3, 31) = 23.646, p<0.0001]. The milled denture group had the highest MMCs at 24 hours when compared to the EWC (p<0.0001), SWC (p=0.001), and SWC2 (p<0.0001) denture groups. SWC had a higher MMC than EWC (p=0.032) and SWC2 (p=0.015). No differences were found in MMCs when comparing EWC and SWC2 (p=0.989). Conclusion: Methylmethacrylate concentrations were significantly lower in 3D-printed RCDs than in milled RCDs when using the resins employed in this study. Furthermore, the MMCs can be further decreased in 3D-printed RCDs when coated with an additional thin protective layer (Durécon) by following the manufacturer-recommended rinsing protocol or when an extended isopropanol wash cycle is adopted. … (more)
- Is Part Of:
- Journal of dentistry. Volume 120(2022)
- Journal:
- Journal of dentistry
- Issue:
- Volume 120(2022)
- Issue Display:
- Volume 120, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 120
- Issue:
- 2022
- Issue Sort Value:
- 2022-0120-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05
- Subjects:
- Removable complete dentures -- CAD-CAM -- Residual monomer content -- CAD-CAM milling -- 3D-printing -- Geriatric dentistry
Dentistry -- Periodicals
Dentistry -- Periodicals
Dentisterie -- Périodiques
Electronic journals
617.6005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03005712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03005712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jdent.2022.104094 ↗
- Languages:
- English
- ISSNs:
- 0300-5712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4968.670000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22183.xml