Echo‐Focusing in Transcranial Focused Ultrasound Thalamotomy for Essential Tremor: A Feasibility Study. Issue 12 (20th August 2020)
- Record Type:
- Journal Article
- Title:
- Echo‐Focusing in Transcranial Focused Ultrasound Thalamotomy for Essential Tremor: A Feasibility Study. Issue 12 (20th August 2020)
- Main Title:
- Echo‐Focusing in Transcranial Focused Ultrasound Thalamotomy for Essential Tremor: A Feasibility Study
- Authors:
- Jones, Ryan M.
Huang, Yuexi
Meng, Ying
Scantlebury, Nadia
Schwartz, Michael L.
Lipsman, Nir
Hynynen, Kullervo - Abstract:
- Abstract: Background: Transcranial magnetic resonance–guided focused ultrasound (TcMRgFUS) systems currently employ computed tomography (CT)–based aberration corrections, which may provide suboptimal trans‐skull focusing. Objectives: The objective of this study was to evaluate a contrast agent microbubble imaging‐based transcranial focusing method, echo‐focusing (EF), during TcMRgFUS for essential tremor. Methods: A clinical trial of TcMRgFUS thalamotomy using EF for the treatment of essential tremor was conducted (NCT03935581; funded by InSightec [Tirat Carmel, Israel]). Patients (n = 12) were injected with Definity (Lantheus Medical Imaging, North Billerica, MA) microbubbles, and EF was performed using a research feature add‐on to a commercial TcMRgFUS system (ExAblate Neuro, InSightec). Subablative thermal sonications carried out using (1) EF and (2) CT‐based aberration corrections were compared via magnetic resonance thermometry, and the optimal focusing method for each patient was employed for TcMRgFUS thalamotomy. Results: EF aberration corrections provided increased sonication efficiency, decreased focal size, and equivalent targeting accuracy relative to CT‐based focusing. EF aberration corrections were employed successfully for lesion formation in all 12 patients, 3 of whom had previously undergone unsuccessful TcMRgFUS thalamotomy via CT‐based focusing. There were no adverse events related directly to the EF procedure. Conclusions: EF is feasible and appears safeAbstract: Background: Transcranial magnetic resonance–guided focused ultrasound (TcMRgFUS) systems currently employ computed tomography (CT)–based aberration corrections, which may provide suboptimal trans‐skull focusing. Objectives: The objective of this study was to evaluate a contrast agent microbubble imaging‐based transcranial focusing method, echo‐focusing (EF), during TcMRgFUS for essential tremor. Methods: A clinical trial of TcMRgFUS thalamotomy using EF for the treatment of essential tremor was conducted (NCT03935581; funded by InSightec [Tirat Carmel, Israel]). Patients (n = 12) were injected with Definity (Lantheus Medical Imaging, North Billerica, MA) microbubbles, and EF was performed using a research feature add‐on to a commercial TcMRgFUS system (ExAblate Neuro, InSightec). Subablative thermal sonications carried out using (1) EF and (2) CT‐based aberration corrections were compared via magnetic resonance thermometry, and the optimal focusing method for each patient was employed for TcMRgFUS thalamotomy. Results: EF aberration corrections provided increased sonication efficiency, decreased focal size, and equivalent targeting accuracy relative to CT‐based focusing. EF aberration corrections were employed successfully for lesion formation in all 12 patients, 3 of whom had previously undergone unsuccessful TcMRgFUS thalamotomy via CT‐based focusing. There were no adverse events related directly to the EF procedure. Conclusions: EF is feasible and appears safe during TcMRgFUS thalamotomy for essential tremor and improves on the trans‐skull focal quality provided by existing CT‐based focusing methods. © 2020 International Parkinson and Movement Disorder Society … (more)
- Is Part Of:
- Movement disorders. Volume 35:Issue 12(2020)
- Journal:
- Movement disorders
- Issue:
- Volume 35:Issue 12(2020)
- Issue Display:
- Volume 35, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 12
- Issue Sort Value:
- 2020-0035-0012-0000
- Page Start:
- 2327
- Page End:
- 2333
- Publication Date:
- 2020-08-20
- Subjects:
- echo‐focusing -- essential tremor -- microbubble contrast agents -- thalamotomy -- transcranial focused ultrasound
Movement disorders -- Periodicals
610 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-8257 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mds.28226 ↗
- Languages:
- English
- ISSNs:
- 0885-3185
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5980.317200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22199.xml