3D-Printed Models versus CT Scan and X-Rays Imaging in the Diagnostic Evaluation of Proximal Humerus Fractures: A Triple-Blind Interobserver Reliability Comparison Study. (13th June 2022)
- Record Type:
- Journal Article
- Title:
- 3D-Printed Models versus CT Scan and X-Rays Imaging in the Diagnostic Evaluation of Proximal Humerus Fractures: A Triple-Blind Interobserver Reliability Comparison Study. (13th June 2022)
- Main Title:
- 3D-Printed Models versus CT Scan and X-Rays Imaging in the Diagnostic Evaluation of Proximal Humerus Fractures: A Triple-Blind Interobserver Reliability Comparison Study
- Authors:
- Puglisi, Gianluca
Montemagno, Marco
Denaro, Regina
Condorelli, Giuseppe
Caruso, Vincenzo Fabrizio
Vescio, Andrea
Testa, Gianluca
Pavone, Vito - Other Names:
- Liuzza Francesco Academic Editor.
- Abstract:
- Abstract : Background . Proximal humerus fractures (PHFs) are one of the most frequent fractures in the elderly and are the third most fractures after those of the hip and wrist. PHFs are assessed clinically through conventionally standard imaging (X-ray and computed tomography (CT) scans). The present study aims to conduct the diagnostic evaluation and therapeutic efficacy of the 3D-printed models (3DPMs) for the PHFs, compared with the standard imaging. Objectives . In terms of fracture classification and surgical indication, PHFs have poor interobserver agreement between orthopedic surgeons using traditional imaging such as X-rays and CT scan. Our objective is to compare interobserver reliability in diagnostic evaluation of PHFs using 3DPMs compared to traditional imaging. Methods . The inclusion criteria were elders aged >65 years, fracture classification AO/OTA 11 B and 11 C, and no pathological fractures or polytrauma. In addition, 9 PHFs were assessed by 6 evaluators through a questionnaire and double-blinded administered for each imaging (X-ray and CT scan) and 3DPMs for each fracture. The questionnaire for each method regarded Neer classification, Hertel classification, treatment indication (IT), and surgical technique (ST). Interobserver reliability was calculated through the intraclass correlation coefficient (ICC). Results . Nine patients with PHF were included in the study (66% female). The Neer and Hertel classifications between imaging types had similar ICCAbstract : Background . Proximal humerus fractures (PHFs) are one of the most frequent fractures in the elderly and are the third most fractures after those of the hip and wrist. PHFs are assessed clinically through conventionally standard imaging (X-ray and computed tomography (CT) scans). The present study aims to conduct the diagnostic evaluation and therapeutic efficacy of the 3D-printed models (3DPMs) for the PHFs, compared with the standard imaging. Objectives . In terms of fracture classification and surgical indication, PHFs have poor interobserver agreement between orthopedic surgeons using traditional imaging such as X-rays and CT scan. Our objective is to compare interobserver reliability in diagnostic evaluation of PHFs using 3DPMs compared to traditional imaging. Methods . The inclusion criteria were elders aged >65 years, fracture classification AO/OTA 11 B and 11 C, and no pathological fractures or polytrauma. In addition, 9 PHFs were assessed by 6 evaluators through a questionnaire and double-blinded administered for each imaging (X-ray and CT scan) and 3DPMs for each fracture. The questionnaire for each method regarded Neer classification, Hertel classification, treatment indication (IT), and surgical technique (ST). Interobserver reliability was calculated through the intraclass correlation coefficient (ICC). Results . Nine patients with PHF were included in the study (66% female). The Neer and Hertel classifications between imaging types had similar ICC values between raters with no statistical differences. IT reliability using CT scan and 3DPMs (ICC = 1; p = 0.116 ) assessed better agreement compared with X-rays IT. The ST reliability using 3DPMs (ICC = 0.755; p = 0.002 ) was statistically superior to traditional imaging (ST-RX ICC = -0.004 (p = 0.454 ); ST-CT ICC = 0.429 p = 0.116 ). Conclusion . Classification systems like Neer and Hertel offer poor reliability between operators. The 3DPMs for evaluating diagnostics are comparable to CT images but superior to the surgical technique agreement. The application of 3DPMs is effective for preoperative fracture planning and the modeling of patient-specific hardware. … (more)
- Is Part Of:
- Advances in orthopedics. Volume 2022(2022)
- Journal:
- Advances in orthopedics
- Issue:
- Volume 2022(2022)
- Issue Display:
- Volume 2022, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 2022
- Issue:
- 2022
- Issue Sort Value:
- 2022-2022-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-13
- Subjects:
- Orthopedics -- Periodicals
Orthopedics
Orthopedic Procedures
Orthopedics
Electronic journals
Periodicals
Periodicals
616.7 - Journal URLs:
- https://www.hindawi.com/journals/aorth/ ↗
http://bibpurl.oclc.org/web/46477 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1600/ ↗
http://dx.doi.org/10.4061/aop ↗ - DOI:
- 10.1155/2022/5863813 ↗
- Languages:
- English
- ISSNs:
- 2090-3464
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 22131.xml