Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T. Issue 2 (28th March 2022)
- Record Type:
- Journal Article
- Title:
- Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T. Issue 2 (28th March 2022)
- Main Title:
- Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T
- Authors:
- McElroy, Sarah
Ferrazzi, Giulio
Nazir, Muhummad Sohaib
Evans, Carl
Ferreira, Joana
Bosio, Filippo
Mughal, Nabila
Kunze, Karl P.
Neji, Radhouene
Speier, Peter
Stäb, Daniel
Ismail, Tevfik F.
Masci, Pier Giorgio
Villa, Adriana D. M.
Razavi, Reza
Chiribiri, Amedeo
Roujol, Sébastien - Abstract:
- Abstract : Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm 2 ) at 1.5T. Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm 2 ) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm 2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs.Abstract : Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm 2 ) at 1.5T. Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm 2 ) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm 2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84). Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 2(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 2(2022)
- Issue Display:
- Volume 88, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 2
- Issue Sort Value:
- 2022-0088-0002-0000
- Page Start:
- 663
- Page End:
- 675
- Publication Date:
- 2022-03-28
- Subjects:
- compressed sensing -- myocardial perfusion -- simultaneous multi‐slice
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29229 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22129.xml