Wide area circumferential ablation for pulmonary vein isolation using radiofrequency versus laser balloon ablation. Issue 3 (6th May 2022)
- Record Type:
- Journal Article
- Title:
- Wide area circumferential ablation for pulmonary vein isolation using radiofrequency versus laser balloon ablation. Issue 3 (6th May 2022)
- Main Title:
- Wide area circumferential ablation for pulmonary vein isolation using radiofrequency versus laser balloon ablation
- Authors:
- Skeete, Jamario
Sharma, Parikshit S.
Kenigsberg, David
Pietrasik, Grzegorz
Osman, Ahmed F.
Ravi, Venkatesh
Du‐Fay‐de‐Lavallaz, Jeanne M.
Post, Zoe
Wasserlauf, Jeremiah
Larsen, Timothy R.
Krishnan, Kousik
Trohman, Richard
Huang, Henry D. - Abstract:
- Abstract: Background: Persistent atrial fibrillation (AF) is associated with high recurrence rates of AF and atypical atrial flutters or tachycardia (AFT) postablation. Laser balloon (LB) ablation of the pulmonary vein (PV) ostia has similar efficacy as radiofrequency wide area circumferential ablation (RF‐WACA); however, an approach of LB wide area circumferential ablation (LB‐WACA) may further improve success rates. Objective: To evaluate freedom from atrial tachyarrhythmia (AFT/AF) recurrence postablation using RF‐WACA versus LB‐WACA in persistent AF patients. Methods: This was a retrospective multicenter study. Patients were followed for up to 24 months via office visits, Holter, and/or device monitoring. The primary endpoint was freedom from AFT/AF after a single ablation procedure. Secondary endpoints included freedom from AF, freedom from AFT, first‐pass isolation of all PVs, and procedural complications. Results: Two hundred and four patients were studied (LB‐WACA: n = 103; RF‐WACA: n = 101). Patients' baseline characteristics were similar except patients in the RF‐WACA group were older (64 vs. 68, p = .03). First‐pass isolation was achieved more often during LBA (LB‐WACA: 88% vs. RF‐WACA 75%; p = .04). Procedure ( p = .36), LA dwell ( p = .41), and fluoroscopy ( p = .44) time were similar. The mean follow‐up was 506 ± 279 days. Sixty‐six patients had arrhythmic events including 24 AFT and 59 AF recurrences. LB‐WACA group had higher arrhythmia‐free survival (Abstract: Background: Persistent atrial fibrillation (AF) is associated with high recurrence rates of AF and atypical atrial flutters or tachycardia (AFT) postablation. Laser balloon (LB) ablation of the pulmonary vein (PV) ostia has similar efficacy as radiofrequency wide area circumferential ablation (RF‐WACA); however, an approach of LB wide area circumferential ablation (LB‐WACA) may further improve success rates. Objective: To evaluate freedom from atrial tachyarrhythmia (AFT/AF) recurrence postablation using RF‐WACA versus LB‐WACA in persistent AF patients. Methods: This was a retrospective multicenter study. Patients were followed for up to 24 months via office visits, Holter, and/or device monitoring. The primary endpoint was freedom from AFT/AF after a single ablation procedure. Secondary endpoints included freedom from AF, freedom from AFT, first‐pass isolation of all PVs, and procedural complications. Results: Two hundred and four patients were studied (LB‐WACA: n = 103; RF‐WACA: n = 101). Patients' baseline characteristics were similar except patients in the RF‐WACA group were older (64 vs. 68, p = .03). First‐pass isolation was achieved more often during LBA (LB‐WACA: 88% vs. RF‐WACA 75%; p = .04). Procedure ( p = .36), LA dwell ( p = .41), and fluoroscopy ( p = .44) time were similar. The mean follow‐up was 506 ± 279 days. Sixty‐six patients had arrhythmic events including 24 AFT and 59 AF recurrences. LB‐WACA group had higher arrhythmia‐free survival ( p = .009) after single ablation procedures. In the multivariate Cox regression model, RF‐WACA was associated with a higher recurrence of AFT compared with LB‐WACA (Adjusted HR 3.16 [95% CI: 1.13–8.83]; p = .03). Conclusions: LB‐WACA was associated with higher freedom from atrial arrhythmias mostly driven by the lower occurrence of AFT compared with RF‐WACA. Abstract : Wide area circumferential ablation is feasible using the laser balloon approach for treatment of patients with atrial fibrillation. Wide area circumferential ablation using laser balloon may be associated with lower rates of atrial flutter/tachycardia recurrence post‐ablation. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 38:Issue 3(2022)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 38:Issue 3(2022)
- Issue Display:
- Volume 38, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2022-0038-0003-0000
- Page Start:
- 336
- Page End:
- 345
- Publication Date:
- 2022-05-06
- Subjects:
- atrial fibrillation -- catheter ablation -- laser ablation -- wide area circumferential ablation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12722 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22127.xml