Multi‐echo balanced SSFP with a sequential phase‐encoding order for functional MR imaging at 7T. Issue 3 (3rd June 2022)
- Record Type:
- Journal Article
- Title:
- Multi‐echo balanced SSFP with a sequential phase‐encoding order for functional MR imaging at 7T. Issue 3 (3rd June 2022)
- Main Title:
- Multi‐echo balanced SSFP with a sequential phase‐encoding order for functional MR imaging at 7T
- Authors:
- Liang, Huilou
Pan, Ziyi
Qian, Chencan
Liu, Chengwen
Sun, Kaibao
Weng, Dehe
An, Jing
Zhuo, Yan
Wang, Danny J. J.
Guo, Hua
Xue, Rong - Abstract:
- Abstract : Purpose: To develop a 2D multi‐echo passband balanced SSFP (bSSFP) sequence using an echo‐train readout with a sequential phase‐encoding order (sequential multi‐echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. Methods: As images of sequential multi‐echo bSSFP exhibit multiple ghosts due to periodic k‐space modulations, a GRAPPA‐based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi‐echo bSSFP and conventional single‐echo bSSFP. Submillimeter‐resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi‐echo bSSFP, conventional single‐echo bSSFP and standard gradient‐echo EPI (GE‐EPI). Results: A higher mean structural similarity index was found between images of single‐echo bSSFP and multi‐echo bSSFP with a shorter echo train length (ETL). Multi‐echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA‐accelerated single‐echo bSSFP ( R = 2). In submillimeter‐resolution fMRI experiments, multi‐echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA‐accelerated single‐echo bSSFP ( R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t ‐value and the number of significantly activated voxels were comparable between GE‐EPI and multi‐echo bSSFP (ETL = 3) that provides virtually distortion‐free functional images and inherits the activationAbstract : Purpose: To develop a 2D multi‐echo passband balanced SSFP (bSSFP) sequence using an echo‐train readout with a sequential phase‐encoding order (sequential multi‐echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. Methods: As images of sequential multi‐echo bSSFP exhibit multiple ghosts due to periodic k‐space modulations, a GRAPPA‐based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi‐echo bSSFP and conventional single‐echo bSSFP. Submillimeter‐resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi‐echo bSSFP, conventional single‐echo bSSFP and standard gradient‐echo EPI (GE‐EPI). Results: A higher mean structural similarity index was found between images of single‐echo bSSFP and multi‐echo bSSFP with a shorter echo train length (ETL). Multi‐echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA‐accelerated single‐echo bSSFP ( R = 2). In submillimeter‐resolution fMRI experiments, multi‐echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA‐accelerated single‐echo bSSFP ( R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t ‐value and the number of significantly activated voxels were comparable between GE‐EPI and multi‐echo bSSFP (ETL = 3) that provides virtually distortion‐free functional images and inherits the activation patterns of conventional bSSFP. Conclusion: Sequential multi‐echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in‐plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 3(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 3(2022)
- Issue Display:
- Volume 88, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 3
- Issue Sort Value:
- 2022-0088-0003-0000
- Page Start:
- 1303
- Page End:
- 1313
- Publication Date:
- 2022-06-03
- Subjects:
- BOLD fMRI -- echo‐train readout -- multi‐echo -- passband balanced SSFP -- submillimeter in‐plane resolution -- ultrahigh field
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29301 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22132.xml