RF coil design for accurate parallel imaging on 13C MRSI using 23Na sensitivity profiles. Issue 3 (30th May 2022)
- Record Type:
- Journal Article
- Title:
- RF coil design for accurate parallel imaging on 13C MRSI using 23Na sensitivity profiles. Issue 3 (30th May 2022)
- Main Title:
- RF coil design for accurate parallel imaging on 13C MRSI using 23Na sensitivity profiles
- Authors:
- Sanchez‐Heredia, Juan D.
Olin, Rie B.
Grist, James T.
Wang, Wenjun
Bøgh, Nikolaj
Zhurbenko, Vitaliy
Hansen, Esben S.
Schulte, Rolf F.
Tyler, Damian
Laustsen, Christoffer
Ardenkjær‐Larsen, Jan H. - Abstract:
- Abstract : Purpose: To develop a coil‐based method to obtain accurate sensitivity profiles in 13 C MRI at 3T from the endogenous 23 Na. An eight‐channel array is designed for 13 C MR acquisitions. As application examples, the array is used for two‐fold accelerated acquisitions of both hyperpolarized 13 C metabolic imaging of pig kidneys and the human brain. Methods: A flexible coil array was tuned optimally for 13 C at 3T (32.1 MHz), with the coil coupling coefficients matched to be nearly identical at the resonance frequency of 23 Na (33.8 MHz). This is done by enforcing a high decoupling (obtained through highly mismatched preamplifiers) and adjusting the coupling frequency response. The SNR performance is compared to reference coils. Results: The measured sensitivity profiles on a phantom showed high spatial similarity for 13 C and 23 Na resonances, with average noise correlation of 9 and 11%, respectively. For acceleration factors 2, 3, and 4, the obtained maximum g‐factors were 1.0, 1.1, and 2.6, respectively. The 23 Na profiles obtained in vivo could be used successfully to perform two‐fold acceleration of hyperpolarized 13 C 3D acquisitions of both pig kidneys and a healthy human brain. Conclusion: A receive array has been developed in such a way that the 13 C sensitivity profiles could be accurately obtained from measurements at the 23 Na frequency. This technique facilitates accelerated acquisitions for hyperpolarized 13 C imaging. The SNR performance obtained atAbstract : Purpose: To develop a coil‐based method to obtain accurate sensitivity profiles in 13 C MRI at 3T from the endogenous 23 Na. An eight‐channel array is designed for 13 C MR acquisitions. As application examples, the array is used for two‐fold accelerated acquisitions of both hyperpolarized 13 C metabolic imaging of pig kidneys and the human brain. Methods: A flexible coil array was tuned optimally for 13 C at 3T (32.1 MHz), with the coil coupling coefficients matched to be nearly identical at the resonance frequency of 23 Na (33.8 MHz). This is done by enforcing a high decoupling (obtained through highly mismatched preamplifiers) and adjusting the coupling frequency response. The SNR performance is compared to reference coils. Results: The measured sensitivity profiles on a phantom showed high spatial similarity for 13 C and 23 Na resonances, with average noise correlation of 9 and 11%, respectively. For acceleration factors 2, 3, and 4, the obtained maximum g‐factors were 1.0, 1.1, and 2.6, respectively. The 23 Na profiles obtained in vivo could be used successfully to perform two‐fold acceleration of hyperpolarized 13 C 3D acquisitions of both pig kidneys and a healthy human brain. Conclusion: A receive array has been developed in such a way that the 13 C sensitivity profiles could be accurately obtained from measurements at the 23 Na frequency. This technique facilitates accelerated acquisitions for hyperpolarized 13 C imaging. The SNR performance obtained at the 13 C frequency, compares well to other state‐of‐the‐art coils for the same purpose, showing slightly better superficial and central SNR. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 3(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 3(2022)
- Issue Display:
- Volume 88, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 3
- Issue Sort Value:
- 2022-0088-0003-0000
- Page Start:
- 1391
- Page End:
- 1405
- Publication Date:
- 2022-05-30
- Subjects:
- flexible RF coil -- hyperpolarization -- parallel Imaging -- X‐Nuclei MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29259 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22132.xml