Free‐breathing self‐gated continuous‐IR spiral T1 mapping: Comparison of dual flip‐angle and Bloch‐Siegert B1‐corrected techniques. Issue 3 (28th April 2022)
- Record Type:
- Journal Article
- Title:
- Free‐breathing self‐gated continuous‐IR spiral T1 mapping: Comparison of dual flip‐angle and Bloch‐Siegert B1‐corrected techniques. Issue 3 (28th April 2022)
- Main Title:
- Free‐breathing self‐gated continuous‐IR spiral T1 mapping: Comparison of dual flip‐angle and Bloch‐Siegert B1‐corrected techniques
- Authors:
- Zhou, Ruixi
Wang, Junyu
Weller, Daniel S.
Yang, Yang
Mugler, John P.
Salerno, Michael - Abstract:
- Abstract : Purpose: To develop a B1‐corrrected single flip‐angle continuous acquisition strategy with free‐breathing and cardiac self‐gating for spiral T1 mapping, and compare it to a previous dual flip‐angle technique. Methods: Data were continuously acquired using a spiral‐out trajectory, rotated by the golden angle in time. During the first 2 s, off‐resonance Fermi RF pulses were applied to generate a Bloch‐Siegert shift B1 map, and the subsequent data were acquired with an inversion RF pulse applied every 4 s to create a T1* map. The final T1 map was generated from the B1 and the T1* maps by using a look‐up table that accounted for slice profile effects, yielding more accurate T1 values. T1 values were compared to those from inversion recovery (IR) spin echo (phantom only), MOLLI, SAturation‐recovery single‐SHot Acquisition (SASHA), and previously proposed dual flip‐angle results. This strategy was evaluated in a phantom and 25 human subjects. Results: The proposed technique showed good agreement with IR spin‐echo results in the phantom experiment. For in‐vivo studies, the proposed technique and the previously proposed dual flip‐angle method were more similar to SASHA results than to MOLLI results. Conclusions: B1‐corrected single flip‐angle T1 mapping successfully acquired B1 and T1 maps in a free‐breathing, continuous‐IR spiral acquisition, providing a method with improved accuracy to measure T1 using a continuous Look‐Locker acquisition, as compared to the previouslyAbstract : Purpose: To develop a B1‐corrrected single flip‐angle continuous acquisition strategy with free‐breathing and cardiac self‐gating for spiral T1 mapping, and compare it to a previous dual flip‐angle technique. Methods: Data were continuously acquired using a spiral‐out trajectory, rotated by the golden angle in time. During the first 2 s, off‐resonance Fermi RF pulses were applied to generate a Bloch‐Siegert shift B1 map, and the subsequent data were acquired with an inversion RF pulse applied every 4 s to create a T1* map. The final T1 map was generated from the B1 and the T1* maps by using a look‐up table that accounted for slice profile effects, yielding more accurate T1 values. T1 values were compared to those from inversion recovery (IR) spin echo (phantom only), MOLLI, SAturation‐recovery single‐SHot Acquisition (SASHA), and previously proposed dual flip‐angle results. This strategy was evaluated in a phantom and 25 human subjects. Results: The proposed technique showed good agreement with IR spin‐echo results in the phantom experiment. For in‐vivo studies, the proposed technique and the previously proposed dual flip‐angle method were more similar to SASHA results than to MOLLI results. Conclusions: B1‐corrected single flip‐angle T1 mapping successfully acquired B1 and T1 maps in a free‐breathing, continuous‐IR spiral acquisition, providing a method with improved accuracy to measure T1 using a continuous Look‐Locker acquisition, as compared to the previously proposed dual excitation flip‐angle technique. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 3(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 3(2022)
- Issue Display:
- Volume 88, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 3
- Issue Sort Value:
- 2022-0088-0003-0000
- Page Start:
- 1068
- Page End:
- 1080
- Publication Date:
- 2022-04-28
- Subjects:
- B1 mapping -- cardiac MRI -- dictionary learning -- free‐breathing -- motion‐correction -- self‐gating -- spiral trajectory -- T1 mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29269 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22132.xml