Two years after pulmonary vein isolation guided by ablation index—a multicenter study. Issue 3 (15th March 2022)
- Record Type:
- Journal Article
- Title:
- Two years after pulmonary vein isolation guided by ablation index—a multicenter study. Issue 3 (15th March 2022)
- Main Title:
- Two years after pulmonary vein isolation guided by ablation index—a multicenter study
- Authors:
- Sousa, Pedro A.
Puga, Luís
Adão, Luís
Primo, João
Khoueiry, Ziad
Lebreiro, Ana
Fonseca, Paulo
Lagrange, Philippe
Elvas, Luís
Gonçalves, Lino - Abstract:
- Abstract: Background: The use of the Ablation Index (AI) software for paroxysmal atrial fibrillation (AF) has been associated with higher acute effectiveness and higher 1‐year arrhythmia freedom. There is, however, a lack of data concerning longer follow‐up. We aim to evaluate the 2‐year outcomes after a standardized AI‐guided pulmonary vein isolation (PVI). Methods: Prospective, multicenter study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. PVI was guided by a tailored AI value (≥500 for anterior segment, ≥450 for the roof segments and inferior segments, and 400 for the posterior wall) and an ILD ≤6 mm. The primary endpoints were acute and long‐term effectiveness. Results: The study included 218 (842 PV) patients (61% males, median age of 60 [IQR 49–68] years) with paroxysmal AF. First‐pass isolation was obtained in 93% of the patients, with an acute reconnection occurring in 10.6% of the patients (3.2% of the PV) following adenosine trial. After a median follow‐up of 26 (IQR 20–30) months, freedom from any documented atrial arrhythmia was 83.4%, off‐AAD. The rate of adverse events was 1.4%. Although procedural parameters differ across centers ( p < 0.001), the acute ( p = 0.56) and long‐term effectiveness ( p = 0.83) were consistent between centers. Conclusions: Patients with paroxysmal AF submitted to an AI‐guided PVI workflow presented high arrhythmia freedom at 2‐years of follow‐up. Abstract : This study presents theAbstract: Background: The use of the Ablation Index (AI) software for paroxysmal atrial fibrillation (AF) has been associated with higher acute effectiveness and higher 1‐year arrhythmia freedom. There is, however, a lack of data concerning longer follow‐up. We aim to evaluate the 2‐year outcomes after a standardized AI‐guided pulmonary vein isolation (PVI). Methods: Prospective, multicenter study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. PVI was guided by a tailored AI value (≥500 for anterior segment, ≥450 for the roof segments and inferior segments, and 400 for the posterior wall) and an ILD ≤6 mm. The primary endpoints were acute and long‐term effectiveness. Results: The study included 218 (842 PV) patients (61% males, median age of 60 [IQR 49–68] years) with paroxysmal AF. First‐pass isolation was obtained in 93% of the patients, with an acute reconnection occurring in 10.6% of the patients (3.2% of the PV) following adenosine trial. After a median follow‐up of 26 (IQR 20–30) months, freedom from any documented atrial arrhythmia was 83.4%, off‐AAD. The rate of adverse events was 1.4%. Although procedural parameters differ across centers ( p < 0.001), the acute ( p = 0.56) and long‐term effectiveness ( p = 0.83) were consistent between centers. Conclusions: Patients with paroxysmal AF submitted to an AI‐guided PVI workflow presented high arrhythmia freedom at 2‐years of follow‐up. Abstract : This study presents the longest follow‐up after pulmonary vein isolation guided by the Ablation Index software; A tailored, standardized AI‐guided demonstrates a low acute pulmonary vein reconnection and an 83% freedom from sustained atrial arrhythmia at 2‐years of follow‐up;The acute and long‐term effectiveness obtained in this study appears to be reproducible across the different centers. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 38:Issue 3(2022)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 38:Issue 3(2022)
- Issue Display:
- Volume 38, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2022-0038-0003-0000
- Page Start:
- 346
- Page End:
- 352
- Publication Date:
- 2022-03-15
- Subjects:
- ablation index -- pulmonary vein isolation -- standardized workflow -- tailored ablation -- two years follow‐up
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12696 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22127.xml