A patient‐friendly 16‐channel transmit/64‐channel receive coil array for combined head–neck MRI at 7 Tesla. Issue 3 (23rd May 2022)
- Record Type:
- Journal Article
- Title:
- A patient‐friendly 16‐channel transmit/64‐channel receive coil array for combined head–neck MRI at 7 Tesla. Issue 3 (23rd May 2022)
- Main Title:
- A patient‐friendly 16‐channel transmit/64‐channel receive coil array for combined head–neck MRI at 7 Tesla
- Authors:
- May, Markus W.
Hansen, Sam‐Luca J. D.
Mahmutovic, Mirsad
Scholz, Alina
Kutscha, Nicolas
Guerin, Bastien
Stockmann, Jason P.
Barry, Robert L.
Kazemivalipour, Ehsan
Gumbrecht, Rene
Kimmlingen, Ralph
Adriany, Markus
Chang, Yulin
Triantafyllou, Christina
Knake, Susanne
Wald, Lawrence L.
Keil, Boris - Abstract:
- Abstract : Purpose: To extend the coverage of brain coil arrays to the neck and cervical–spine region to enable combined head and neck imaging at 7 Tesla (T) ultra‐high field MRI. Methods: The coil array structures of a 64‐channel receive coil and a 16‐channel transmit coil were merged into one anatomically shaped close‐fitting housing. Transmit characteristics were evaluated in a B 1 + ‐field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head–neck array coil was demonstrated in human volunteers using high‐resolution accelerated imaging. Results: In the brain, the SNR matches the commercially available 32‐channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32‐channel brain arrays at 7 T. The interelement coupling of the 16‐channel transmit coil ranged from −14 to −44 dB (mean = −19 dB, adjacent elements <−18 dB). The parallel 16‐channel transmit coil greatly facilitates B 1 + field shaping required for large FOV neuroimaging at 7 T. Conclusion: This new head–neck array coil is the first demonstration of a device of this nature used for combined full‐brain, head–neck, and cervical‐spine imaging at 7 T.Abstract : Purpose: To extend the coverage of brain coil arrays to the neck and cervical–spine region to enable combined head and neck imaging at 7 Tesla (T) ultra‐high field MRI. Methods: The coil array structures of a 64‐channel receive coil and a 16‐channel transmit coil were merged into one anatomically shaped close‐fitting housing. Transmit characteristics were evaluated in a B 1 + ‐field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head–neck array coil was demonstrated in human volunteers using high‐resolution accelerated imaging. Results: In the brain, the SNR matches the commercially available 32‐channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32‐channel brain arrays at 7 T. The interelement coupling of the 16‐channel transmit coil ranged from −14 to −44 dB (mean = −19 dB, adjacent elements <−18 dB). The parallel 16‐channel transmit coil greatly facilitates B 1 + field shaping required for large FOV neuroimaging at 7 T. Conclusion: This new head–neck array coil is the first demonstration of a device of this nature used for combined full‐brain, head–neck, and cervical‐spine imaging at 7 T. The array coil is well suited to provide large FOV images, which potentially improves ultrahigh field neuroimaging applications for clinical settings. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 3(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 3(2022)
- Issue Display:
- Volume 88, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 3
- Issue Sort Value:
- 2022-0088-0003-0000
- Page Start:
- 1419
- Page End:
- 1433
- Publication Date:
- 2022-05-23
- Subjects:
- 7 Tesla (7T) -- head and neck -- MRI -- neuroimaging -- array coil -- ultrahigh field (UHF)
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29288 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22132.xml