Real‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways. Issue 2 (10th April 2022)
- Record Type:
- Journal Article
- Title:
- Real‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways. Issue 2 (10th April 2022)
- Main Title:
- Real‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways
- Authors:
- Töger, Johannes
Andersen, Mads
Haglund, Olle
Kylkilahti, Tekla Maria
Lundgaard, Iben
Markenroth Bloch, Karin - Abstract:
- Abstract : Purpose: Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions. Methods: A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers ( n = 10) were scanned at four different respiratory conditions, including repeat scans. Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference Q R = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio Q C = 0.46 ± 0.14). Simulations suggest that Q C can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak toAbstract : Purpose: Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions. Methods: A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers ( n = 10) were scanned at four different respiratory conditions, including repeat scans. Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference Q R = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio Q C = 0.46 ± 0.14). Simulations suggest that Q C can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48–0.90). Net flow was influenced by respiratory condition ( p < 0.01). Conclusions: The presented real‐time flow MRI method can quantify respiratory‐related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 2(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 2(2022)
- Issue Display:
- Volume 88, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 2
- Issue Sort Value:
- 2022-0088-0002-0000
- Page Start:
- 770
- Page End:
- 786
- Publication Date:
- 2022-04-10
- Subjects:
- cerebrospinal fluid -- CSF -- flow -- magnetic resonance imaging -- MRI -- real‐time
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29248 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22129.xml