Quantitation of Phenolic Benzotriazole Class Compounds in Plasma by Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS). (2nd September 2022)
- Record Type:
- Journal Article
- Title:
- Quantitation of Phenolic Benzotriazole Class Compounds in Plasma by Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS). (2nd September 2022)
- Main Title:
- Quantitation of Phenolic Benzotriazole Class Compounds in Plasma by Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS)
- Authors:
- Mutlu, Esra
South, Natalie
Pierfelice, Jessica
Djonabaye, Alison
Pauff, Mindy
Burback, Brian
Waidyanatha, Suramya - Abstract:
- Abstract: Phenolic benzotriazoles are used as ultraviolet stabilizers in consumer products and have been detected in the environment suggesting potential human exposure. Phenolic benzotriazoles were nominated to the Division of National Toxicology Program for testing based on their potential widespread human exposure and lack of adequate toxicity data. Nine chemicals were selected for toxicological evaluation, representing unsubstituted (2-(2H-benzotriazole-2-yl)phenol, (P-BZT)), monosubstituted (drometrizole; 2-(2H-benzotriazol-2-yl)-4-tert-butylphenol (tBu-BZT); octrizole), disubstituted (2-(2H-benzotriazol-2-yl)-4, 6-bis(1-methyl-1-phenylethyl)phenol (diMeEtPh-BZT), 2-(2H-benzotriazol-2-yl)-4, 6-bis(1, 1-dimethylpropyl)phenol (ditPe-BZT); 3-(2H-benzotriazol-2-yl)-5-(1, 1-dimethylethyl)-4-hydroxybenzenepropanoic acid, octylester (tBuPrOcEst-BZT) and halogenated trisubstituted (bumetrizole; 2-(5-chloro-2H-benzotriazol-2-yl)-4, 6-bis(1, 1-dimethylethyl)phenol (ditBuCl-BZT)) compounds. Different extraction methods were utilized and methods were developed to determine phenolic benzotriazoles by quantitating free (unconjugated parent) and total (free and conjugated parent) analytes in plasma of rats to aid in interpretation of toxicity data, understanding of absorption, distribution, metabolism, and excretion differences. The calibration standard range was from 1 to 500 ng/mL for free analytes and 1 to 1000 ng/mL for total analytes. The methods were linear (r 2 ≥ 0.99). TheAbstract: Phenolic benzotriazoles are used as ultraviolet stabilizers in consumer products and have been detected in the environment suggesting potential human exposure. Phenolic benzotriazoles were nominated to the Division of National Toxicology Program for testing based on their potential widespread human exposure and lack of adequate toxicity data. Nine chemicals were selected for toxicological evaluation, representing unsubstituted (2-(2H-benzotriazole-2-yl)phenol, (P-BZT)), monosubstituted (drometrizole; 2-(2H-benzotriazol-2-yl)-4-tert-butylphenol (tBu-BZT); octrizole), disubstituted (2-(2H-benzotriazol-2-yl)-4, 6-bis(1-methyl-1-phenylethyl)phenol (diMeEtPh-BZT), 2-(2H-benzotriazol-2-yl)-4, 6-bis(1, 1-dimethylpropyl)phenol (ditPe-BZT); 3-(2H-benzotriazol-2-yl)-5-(1, 1-dimethylethyl)-4-hydroxybenzenepropanoic acid, octylester (tBuPrOcEst-BZT) and halogenated trisubstituted (bumetrizole; 2-(5-chloro-2H-benzotriazol-2-yl)-4, 6-bis(1, 1-dimethylethyl)phenol (ditBuCl-BZT)) compounds. Different extraction methods were utilized and methods were developed to determine phenolic benzotriazoles by quantitating free (unconjugated parent) and total (free and conjugated parent) analytes in plasma of rats to aid in interpretation of toxicity data, understanding of absorption, distribution, metabolism, and excretion differences. The calibration standard range was from 1 to 500 ng/mL for free analytes and 1 to 1000 ng/mL for total analytes. The methods were linear (r 2 ≥ 0.99). The accuracy was determined as the relative error (RE) and ranged from −18.2 to +17.8, and precision as the relative standard deviation (RSD) and ranged from 0.0 to 20.1% for both free and total plasma calibration standards, respectively. The limits of quantitation were ≤5.0 and 10.0 ng/mL and limit of detection ≤ 1.2 and 2.0 ng/mL, for free and total analytes, respectively. These results demonstrate that the methods are suitable for quantitation of free and total analytes in rat plasma. … (more)
- Is Part Of:
- Analytical letters. Volume 55:Number 13(2022)
- Journal:
- Analytical letters
- Issue:
- Volume 55:Number 13(2022)
- Issue Display:
- Volume 55, Issue 13 (2022)
- Year:
- 2022
- Volume:
- 55
- Issue:
- 13
- Issue Sort Value:
- 2022-0055-0013-0000
- Page Start:
- 2074
- Page End:
- 2088
- Publication Date:
- 2022-09-02
- Subjects:
- High-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) -- phenolic benzotriazole -- plasma -- validation
Chemistry, Analytic -- Periodicals
Chemistry, Analytic -- Abstracts
543 - Journal URLs:
- http://www.tandfonline.com/toc/lanl20/current ↗
http://taylorandfrancis.metapress.com/link.asp?id=107818, ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00032719.2022.2044348 ↗
- Languages:
- English
- ISSNs:
- 0003-2719
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22133.xml