Repeatability and reproducibility of the galilei G6 and its agreement with the pentacam® AXL in optical biometry and corneal tomography. (3rd April 2022)
- Record Type:
- Journal Article
- Title:
- Repeatability and reproducibility of the galilei G6 and its agreement with the pentacam® AXL in optical biometry and corneal tomography. (3rd April 2022)
- Main Title:
- Repeatability and reproducibility of the galilei G6 and its agreement with the pentacam® AXL in optical biometry and corneal tomography
- Authors:
- Moshirfar, Majid
Tenney, Stephen
McCabe, Shannon
Schmid, Gregor - Abstract:
- ABSTRACT: Objectives: To assess the repeatability and reproducibility of corneal measurements performed by the Galilei G6 and determine its agreement with the Pentacam® AXL. Methods: 105 eyes underwent examination by both devices, measuring nine parameters. Paired t-tests, Deming Regression, and Bland-Altman plots were used to determine agreement. Analysis of Variance was used to determine repeatability and reproducibility. Results: Measurements showed no clinically significant differences between the two devices. On average, the Galilei G6 measured axial length longer than the Pentacam® AXL by 0.05 mm ± 0.03 mm (p < 0.001), just 0.2% of the mean value and therefore clinically insignificant. It measured central corneal thickness and anterior chamber depth 3.77 μm ± 7.71 μm longer (p < 0.001) and 0.04 mm ± 0.07 μm shorter (p < 0.001), respectively. They are also clinically insignificant, constituting just 0.7% and 1% of the mean values. The results showed evidence of repeatability and reproducibility. Only measurements of corneal cylinder showed some clinically significant variance. Conclusions: The Galilei G6 and Pentacam® AXL measurements show evidence of repeatability, reproducibility, and agreement for examined parameters. Certain caution needs to be applied in cases with moderate or severe corneal cylinder, due to discrepancies in repeatability and reproducibility of corneal cylinder measurements with the Galilei G6.
- Is Part Of:
- Expert review of medical devices. Volume 19:Number 4(2022)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 19:Number 4(2022)
- Issue Display:
- Volume 19, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 19
- Issue:
- 4
- Issue Sort Value:
- 2022-0019-0004-0000
- Page Start:
- 375
- Page End:
- 383
- Publication Date:
- 2022-04-03
- Subjects:
- Scheimpflug imaging -- placido's disc -- topography -- anterior chamber -- corneal cylinder -- keratoconus -- corneal thickness -- White-toWhite/Horizontal limbus diameter -- optical biometry -- tomography
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2022.2075725 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 22120.xml