Comparing GENEActiv against Actiwatch-2 over Seven Nights Using a Common Sleep Scoring Algorithm and Device-Specific Wake Thresholds. Issue 4 (4th July 2022)
- Record Type:
- Journal Article
- Title:
- Comparing GENEActiv against Actiwatch-2 over Seven Nights Using a Common Sleep Scoring Algorithm and Device-Specific Wake Thresholds. Issue 4 (4th July 2022)
- Main Title:
- Comparing GENEActiv against Actiwatch-2 over Seven Nights Using a Common Sleep Scoring Algorithm and Device-Specific Wake Thresholds
- Authors:
- Jenkins, Claire A.
Tiley, Lucy C. F.
Lay, Isabella
Hartmann, Jessica A.
Chan, Julia K. M.
Nicholas, Christian L. - Abstract:
- ABSTRACT: Demonstrating inter-device reliability is essential to use devices interchangeably, and accurately integrate, interpret, or compare data from different actigraphs. Despite this, there is a paucity of comparative literature over a timeframe exceeding one night. The aims of this study were to determine an optimal wake threshold for GENEActiv and to evaluate the concordance between Actiwatch-2 and GENEActiv using a common algorithm (Phillips Respironics). Data were collected from 33 individuals (20 female) aged 20–35 years ( M = 25.33, SD = 4.69) across a total 213 nights. Participants wore both devices simultaneously and continuously for seven days. The sleep parameters of interest were: total sleep time, sleep efficiency, sleep onset latency, and wake after sleep onset. Exploratory analyses of sensitivity, specificity, overall accuracy, mean bias, and paired samples t-tests indicated an optimal wake threshold of 115 for GENEActiv, compared with Actiwatch-2 at the 40 (medium, default) threshold. Using these thresholds, sensitivity, and overall accuracy of GENEActiv were both good (86% and 78%, respectively), however specificity was relatively low (40%). There were no significant inter-device differences for any sleep parameters, and all absolute mean biases were small. Overall, the findings from this study provide the first empirical evidence to support the reliability of GENEActiv against Actiwatch-2 over multiple nights using a common algorithm with device-specificABSTRACT: Demonstrating inter-device reliability is essential to use devices interchangeably, and accurately integrate, interpret, or compare data from different actigraphs. Despite this, there is a paucity of comparative literature over a timeframe exceeding one night. The aims of this study were to determine an optimal wake threshold for GENEActiv and to evaluate the concordance between Actiwatch-2 and GENEActiv using a common algorithm (Phillips Respironics). Data were collected from 33 individuals (20 female) aged 20–35 years ( M = 25.33, SD = 4.69) across a total 213 nights. Participants wore both devices simultaneously and continuously for seven days. The sleep parameters of interest were: total sleep time, sleep efficiency, sleep onset latency, and wake after sleep onset. Exploratory analyses of sensitivity, specificity, overall accuracy, mean bias, and paired samples t-tests indicated an optimal wake threshold of 115 for GENEActiv, compared with Actiwatch-2 at the 40 (medium, default) threshold. Using these thresholds, sensitivity, and overall accuracy of GENEActiv were both good (86% and 78%, respectively), however specificity was relatively low (40%). There were no significant inter-device differences for any sleep parameters, and all absolute mean biases were small. Overall, the findings from this study provide the first empirical evidence to support the reliability of GENEActiv against Actiwatch-2 over multiple nights using a common algorithm with device-specific wake thresholds. … (more)
- Is Part Of:
- Behavioral sleep medicine. Volume 20:Issue 4(2022)
- Journal:
- Behavioral sleep medicine
- Issue:
- Volume 20:Issue 4(2022)
- Issue Display:
- Volume 20, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2022-0020-0004-0000
- Page Start:
- 369
- Page End:
- 379
- Publication Date:
- 2022-07-04
- Subjects:
- Sleep disorders -- Periodicals
Sleep -- Psychological aspects -- Periodicals
616.8498 - Journal URLs:
- http://www.tandfonline.com/toc/hbsm20/current ↗
http://www.informaworld.com/smpp/title~db=all~content=t775648093~tab=issueslist ↗
http://firstsearch.oclc.org ↗
http://www.erlbaum.com ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/15402002.2021.1924175 ↗
- Languages:
- English
- ISSNs:
- 1540-2002
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1877.925000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22118.xml