Tailoring the biologic responses of 3D printed PEEK medical implants by plasma functionalization. Issue 7 (July 2022)
- Record Type:
- Journal Article
- Title:
- Tailoring the biologic responses of 3D printed PEEK medical implants by plasma functionalization. Issue 7 (July 2022)
- Main Title:
- Tailoring the biologic responses of 3D printed PEEK medical implants by plasma functionalization
- Authors:
- Han, Xingting
Sharma, Neha
Spintzyk, Sebastian
Zhou, Yongsheng
Xu, Zeqian
Thieringer, Florian M.
Rupp, Frank - Abstract:
- Abstract: Objective: The objective of this study was to determine the effect of two plasma surface treatments on the biologic responses of PEEK medical implants manufactured by fused filament fabrication (FFF) 3D printing technology. Methods: This study created standard PEEK samples using an FFF 3D printer. After fabrication, half of the samples were polished to simulate a smooth PEEK surface. Then, argon (Ar) or oxygen (O2 ) plasma was used to modify the bioactivity of FFF 3D printed and polished PEEK samples. Scanning electron microscopy (SEM) and a profilometer were used to determine the microstructure and roughness of the sample surfaces. The wettability of the sample surface was assessed using a drop shape analyzer (DSA) after plasma treatment and at various time points following storage in a closed environment. Cell adhesion, metabolic activity, proliferation, and osteogenic differentiation of SAOS-2 osteoblasts were evaluated to determine the in vitro osteogenic activity. Results: SEM analysis revealed that several spherical nanoscale particles and humps appeared on sample surfaces following plasma treatment. The wettability measurement demonstrated that plasma surface treatment significantly increased the surface hydrophilicity of PEEK samples, with only a slight aging effect found after 21 days. Cell adhesion, spreading, proliferation, and differentiation of SAOS-2 osteoblasts were also up-regulated after plasma treatment. Additionally, PEEK samples treated with O2Abstract: Objective: The objective of this study was to determine the effect of two plasma surface treatments on the biologic responses of PEEK medical implants manufactured by fused filament fabrication (FFF) 3D printing technology. Methods: This study created standard PEEK samples using an FFF 3D printer. After fabrication, half of the samples were polished to simulate a smooth PEEK surface. Then, argon (Ar) or oxygen (O2 ) plasma was used to modify the bioactivity of FFF 3D printed and polished PEEK samples. Scanning electron microscopy (SEM) and a profilometer were used to determine the microstructure and roughness of the sample surfaces. The wettability of the sample surface was assessed using a drop shape analyzer (DSA) after plasma treatment and at various time points following storage in a closed environment. Cell adhesion, metabolic activity, proliferation, and osteogenic differentiation of SAOS-2 osteoblasts were evaluated to determine the in vitro osteogenic activity. Results: SEM analysis revealed that several spherical nanoscale particles and humps appeared on sample surfaces following plasma treatment. The wettability measurement demonstrated that plasma surface treatment significantly increased the surface hydrophilicity of PEEK samples, with only a slight aging effect found after 21 days. Cell adhesion, spreading, proliferation, and differentiation of SAOS-2 osteoblasts were also up-regulated after plasma treatment. Additionally, PEEK samples treated with O2 plasma demonstrated a higher degree of bioactivation than those treated with Ar. Significance: Plasma-modified PEEK based on FFF 3D printing technology was a feasible and prospective bone grafting material for bone/dental implants. Graphical Abstract: ga1 Highlights: This study applied plasma surface treatment on FFF 3D printed PEEK samples. Observed slight aging suggests chairside plasma treatments. Plasma surface treatment could tailor the bioactivity of PEEK material. O2 plasma-treated PEEK samples indicated better bioactivation than Ar plasma. Plasma modified PEEK based on the FFF technology is a promising medical implant. … (more)
- Is Part Of:
- Dental materials. Volume 38:Issue 7(2022)
- Journal:
- Dental materials
- Issue:
- Volume 38:Issue 7(2022)
- Issue Display:
- Volume 38, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 7
- Issue Sort Value:
- 2022-0038-0007-0000
- Page Start:
- 1083
- Page End:
- 1098
- Publication Date:
- 2022-07
- Subjects:
- Polyetheretherketone -- Fused Filament Fabrication -- Plasma surface treatment -- Wettability -- Bioactivity
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2022.04.026 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22100.xml