Research on new treatment mode of radiotherapy based on pseudo-medical images. (June 2022)
- Record Type:
- Journal Article
- Title:
- Research on new treatment mode of radiotherapy based on pseudo-medical images. (June 2022)
- Main Title:
- Research on new treatment mode of radiotherapy based on pseudo-medical images
- Authors:
- Sun, Hongfei
Xi, Qianyi
Sun, Jiawei
Fan, Rongbo
Xie, Kai
Ni, Xinye
Yang, Jianhua - Abstract:
- Highlights: Referring to the StarGAN network architecture and proposes, a new radiotherapy treatment mode based on the triangular GAN (TGAN) model to synthesize pseudo-medical images, which solves the problem of image synthesis between multiple data sets and multiple domains. The model receives the training data of MRI, CT, and CBCT image domain, only needs to train a generator, which can synthesize the image data required in the entire radiotherapy process. The TGAN model based on multi-scale discriminant network was used for data training between different image domains. The generator of the TGAN model refers to cGAN and CycleGAN, and only one generation network can establish the non-linear mapping relationship between multiple image domains. The discriminator used multi-scale discrimination network to guide the generator to synthesize pseudo-medical images that are similar to real images from both shallow and deep aspects. The accuracy of pseudo-medical images was verified in anatomy and dosimetry. Abstract: Background and objective: Multi-modal medical images with multiple feature information are beneficial for radiotherapy. A new radiotherapy treatment mode based on triangle generative adversarial network (TGAN) model was proposed to synthesize pseudo-medical images between multi-modal datasets. Methods: CBCT, MRI and CT images of 80 patients with nasopharyngeal carcinoma were selected. The TGAN model based on multi-scale discriminant network was used for data trainingHighlights: Referring to the StarGAN network architecture and proposes, a new radiotherapy treatment mode based on the triangular GAN (TGAN) model to synthesize pseudo-medical images, which solves the problem of image synthesis between multiple data sets and multiple domains. The model receives the training data of MRI, CT, and CBCT image domain, only needs to train a generator, which can synthesize the image data required in the entire radiotherapy process. The TGAN model based on multi-scale discriminant network was used for data training between different image domains. The generator of the TGAN model refers to cGAN and CycleGAN, and only one generation network can establish the non-linear mapping relationship between multiple image domains. The discriminator used multi-scale discrimination network to guide the generator to synthesize pseudo-medical images that are similar to real images from both shallow and deep aspects. The accuracy of pseudo-medical images was verified in anatomy and dosimetry. Abstract: Background and objective: Multi-modal medical images with multiple feature information are beneficial for radiotherapy. A new radiotherapy treatment mode based on triangle generative adversarial network (TGAN) model was proposed to synthesize pseudo-medical images between multi-modal datasets. Methods: CBCT, MRI and CT images of 80 patients with nasopharyngeal carcinoma were selected. The TGAN model based on multi-scale discriminant network was used for data training between different image domains. The generator of the TGAN model refers to cGAN and CycleGAN, and only one generation network can establish the non-linear mapping relationship between multiple image domains. The discriminator used multi-scale discrimination network to guide the generator to synthesize pseudo-medical images that are similar to real images from both shallow and deep aspects. The accuracy of pseudo-medical images was verified in anatomy and dosimetry. Results: In the three synthetic directions, namely, CBCT → CT, CBCT → MRI, and MRI → CT, significant differences ( p < 0.05) in the three-fold-cross validation results on PSNR and SSIM metrics between the pseudo-medical images obtained based on TGAN and the real images. In the testing stage, for TGAN, the MAE metric results in the three synthesis directions (CBCT → CT, CBCT → MRI, and MRI → CT) were presented as mean (standard deviation), which were 68.67 (5.83), 83.14 (8.48), and 79.96 (7.59), and the NMI metric results were 0.8643 (0.0253), 0.8051 (0.0268), and 0.8146 (0.0267) respectively. In terms of dose verification, the differences in dose distribution between the pseudo-CT obtained by TGAN and the real CT were minimal. The H values of the measurement results of dose uncertainty in PGTV, PGTVnd, PTV1, and PTV2 were 42.510, 43.121, 17.054, and 7.795, respectively ( P < 0.05). The differences were statistically significant. The gamma pass rate (2%/2 mm) of pseudo-CT obtained by the new model was 94.94% (0.73%), and the numerical results were better than those of the three other comparison models. Conclusions: The pseudo-medical images acquired based on TGAN were close to the real images in anatomy and dosimetry. The pseudo-medical images synthesized by the TGAN model have good application prospects in clinical adaptive radiotherapy. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 221(2022)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 221(2022)
- Issue Display:
- Volume 221, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 221
- Issue:
- 2022
- Issue Sort Value:
- 2022-0221-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Pseudo medical images -- Generative adversarial network -- Radiotherapy
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.106932 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22100.xml