Planar array magnetic induction tomography further improvement. Issue 2 (9th October 2018)
- Record Type:
- Journal Article
- Title:
- Planar array magnetic induction tomography further improvement. Issue 2 (9th October 2018)
- Main Title:
- Planar array magnetic induction tomography further improvement
- Authors:
- Li, F.
Soleimani, M.
Abascal, J. - Abstract:
- Abstract : Purpose: Magnetic induction tomography (MIT) is a tomographic imaging technique with a wide range of potential industrial applications. Planar array MIT is a convenient setup but unable to access freely from the entire periphery as it only collects measurements from one surface, so it remains challenging given the limited data. This study aims to assess the use of sparse regularization methods for accurate position and depth detection in planar array MIT. Design/methodology/approach: The most difficult challenges in MIT are to solve the inverse and forward problems. The inversion of planar MIT is severely ill-posed due to limited access data. Thus, this paper posed a total variation (TV) problem and solved it efficiently with the Split Bregman formulation to overcome this difficulty. Both isotropic and anisotropic TV formulations are compared to Tikhonov regularization with experimental MIT data. Findings: The results show that Tikhonov method failed or underestimated the object position and depth. Both isotropic and anisotropic TV led to accurate recovery of depth and position. Originality/value: There are numerous potential applications for planar array MIT where access to the materials under testing is restrict. Sparse regularization methods are a promising approach to improving depth detection for limited MIT data.
- Is Part Of:
- Sensor review. Volume 39:Issue 2(2019)
- Journal:
- Sensor review
- Issue:
- Volume 39:Issue 2(2019)
- Issue Display:
- Volume 39, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2019-0039-0002-0000
- Page Start:
- 257
- Page End:
- 268
- Publication Date:
- 2018-10-09
- Subjects:
- Anisotropic TV -- Isotropic TV -- Magnetic induction tomography -- Planar array MIT system -- Total variation
Sensor systems -- Periodicals
Detectors -- Industrial applications -- Periodicals
Engineering instruments -- Periodicals
681.2 - Journal URLs:
- http://www.emeraldinsight.com/journals.htm?issn=0260-2288 ↗
http://www.emeraldinsight.com/ ↗ - DOI:
- 10.1108/SR-02-2018-0027 ↗
- Languages:
- English
- ISSNs:
- 0260-2288
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8241.782000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22073.xml