Non‐Cartesian GRAPPA and coil combination using interleaved calibration data – application to concentric‐ring MRSI of the human brain at 7T. Issue 5 (10th June 2019)
- Record Type:
- Journal Article
- Title:
- Non‐Cartesian GRAPPA and coil combination using interleaved calibration data – application to concentric‐ring MRSI of the human brain at 7T. Issue 5 (10th June 2019)
- Main Title:
- Non‐Cartesian GRAPPA and coil combination using interleaved calibration data – application to concentric‐ring MRSI of the human brain at 7T
- Authors:
- Moser, Philipp
Bogner, Wolfgang
Hingerl, Lukas
Heckova, Eva
Hangel, Gilbert
Motyka, Stanislav
Trattnig, Siegfried
Strasser, Bernhard - Abstract:
- Abstract : Purpose: Proton MR spectroscopic imaging (MRSI) benefits from B 0 ≥ 7T and multichannel receive coils, promising substantial resolution improvements. However, MRSI acquisition with high spatial resolution requires efficient acceleration and coil combination. To speed up the already‐fast sampling via concentric rings, we implemented additional, non‐Cartesian, hybrid through‐time/through‐k‐space (tt/tk)‐generalized autocalibrating partially parallel acquisition (GRAPPA). A new multipurpose interleaved calibration scan (interleaved MUSICAL) acquires reference data for both coil combination and PI. This renders the reconstruction process (especially PI) less sensitive to instabilities. Methods: Six healthy volunteers were scanned at 7T. Three calibration datasets for coil combination and PI were recorded: a) iMUSICAL, b) static MUSICAL as prescan, c) moved MUSICAL as prescan with misaligned head position. The coil combination performance, including motion sensitivity, of iMUSICAL was compared to MUSICAL for single‐slice free induction decay (FID)‐MRSI. Through‐time/through‐k‐space‐GRAPPA with constant/variable‐density undersampling was evaluated on the same data, comparing the three calibration datasets. Additionally, the proposed method was successfully applied to 3D whole‐brain FID‐MRSI. Results: Using iMUSICAL for coil combination yielded the highest signal‐to‐noise ratio (SNR) (+9%) and lowest Cramer‐Rao lower bounds (CRLBs) (‐6%) compared to both MUSICALAbstract : Purpose: Proton MR spectroscopic imaging (MRSI) benefits from B 0 ≥ 7T and multichannel receive coils, promising substantial resolution improvements. However, MRSI acquisition with high spatial resolution requires efficient acceleration and coil combination. To speed up the already‐fast sampling via concentric rings, we implemented additional, non‐Cartesian, hybrid through‐time/through‐k‐space (tt/tk)‐generalized autocalibrating partially parallel acquisition (GRAPPA). A new multipurpose interleaved calibration scan (interleaved MUSICAL) acquires reference data for both coil combination and PI. This renders the reconstruction process (especially PI) less sensitive to instabilities. Methods: Six healthy volunteers were scanned at 7T. Three calibration datasets for coil combination and PI were recorded: a) iMUSICAL, b) static MUSICAL as prescan, c) moved MUSICAL as prescan with misaligned head position. The coil combination performance, including motion sensitivity, of iMUSICAL was compared to MUSICAL for single‐slice free induction decay (FID)‐MRSI. Through‐time/through‐k‐space‐GRAPPA with constant/variable‐density undersampling was evaluated on the same data, comparing the three calibration datasets. Additionally, the proposed method was successfully applied to 3D whole‐brain FID‐MRSI. Results: Using iMUSICAL for coil combination yielded the highest signal‐to‐noise ratio (SNR) (+9%) and lowest Cramer‐Rao lower bounds (CRLBs) (‐6%) compared to both MUSICAL approaches, with similar metabolic map quality. Also, excellent mean g‐factors of 1.07 and low residual lipid aliasing were obtained when using iMUSICAL as calibration data for two‐fold, variable‐density undersampling, while significantly degraded metabolic maps were obtained using the misaligned MUSICAL calibration data. Conclusion: Through‐time/through‐k‐space‐GRAPPA can accelerate already time‐efficient non‐Cartesian spatial‐spectral 2D/3D‐MRSI encoding even further. Particularly promising results have been achieved using iMUSICAL as a robust, interleaved multipurpose calibration for MRSI reconstruction, without extra calibration prescan. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 5(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 5(2019)
- Issue Display:
- Volume 82, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 5
- Issue Sort Value:
- 2019-0082-0005-0000
- Page Start:
- 1587
- Page End:
- 1603
- Publication Date:
- 2019-06-10
- Subjects:
- 7 tesla -- hybrid through‐time/through‐k‐space GRAPPA -- MR spectroscopic imaging -- multichannel coil combination -- non‐Cartesian concentric ring -- parallel imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27822 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22060.xml