Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non‐isocentric scanned proton beam treatments. Issue 2 (29th December 2019)
- Record Type:
- Journal Article
- Title:
- Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non‐isocentric scanned proton beam treatments. Issue 2 (29th December 2019)
- Main Title:
- Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non‐isocentric scanned proton beam treatments
- Authors:
- Grevillot, Loïc
Osorio Moreno, Jhonnatan
Letellier, Virgile
Dreindl, Ralf
Elia, Alessio
Fuchs, Hermann
Carlino, Antonio
Kragl, Gabriele
Palmans, Hugo
Vatnitsky, Stanislav
Stock, Markus - Abstract:
- Abstract : Purpose: This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non‐isocentric scanned proton beam treatments. Methods: Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including advanced measurement methods of intra‐spill beam variations, are defined. Beam monitor calibration using two independent methods based on a dose‐area product formalism is described. Emphasis is given to the medical commissioning work and the specificities related to non‐isocentric irradiation, since a key feature of MedAustron is the routine delivery of non‐isocentric scanned proton beam treatments. Results: Key commissioning results and beam stability trend lines for more than 2 yr of clinical operation have been provided. Intra‐spill beam range, size, and position variations were within specifications of 0.3 mm, 15%, and 0.5 mm, respectively. The agreement between two independent beam monitor calibration methods was better than 1.0%. Non‐isocentric treatment delivery allowed lateral penumbra reduction of up to about 30%. Daily QA measurements of the beam range, size, position, and dose were always within 1 mm, 10%, 1 mm, and 2% from the baseline data, respectively. Conclusions: Non‐isocentric treatments have been successfully implemented at MedAustron for routine scanned proton beam therapy using horizontal and vertical fixed beamlines. Up to nowAbstract : Purpose: This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non‐isocentric scanned proton beam treatments. Methods: Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including advanced measurement methods of intra‐spill beam variations, are defined. Beam monitor calibration using two independent methods based on a dose‐area product formalism is described. Emphasis is given to the medical commissioning work and the specificities related to non‐isocentric irradiation, since a key feature of MedAustron is the routine delivery of non‐isocentric scanned proton beam treatments. Results: Key commissioning results and beam stability trend lines for more than 2 yr of clinical operation have been provided. Intra‐spill beam range, size, and position variations were within specifications of 0.3 mm, 15%, and 0.5 mm, respectively. The agreement between two independent beam monitor calibration methods was better than 1.0%. Non‐isocentric treatment delivery allowed lateral penumbra reduction of up to about 30%. Daily QA measurements of the beam range, size, position, and dose were always within 1 mm, 10%, 1 mm, and 2% from the baseline data, respectively. Conclusions: Non‐isocentric treatments have been successfully implemented at MedAustron for routine scanned proton beam therapy using horizontal and vertical fixed beamlines. Up to now every patient was treated in non‐isocentric conditions. The presented methodology to implement a new Scanned Ion Beam Delivery (SIBD) system into clinical routine for proton therapy may serve as a guidance for other centers. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 2(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 2(2020)
- Issue Display:
- Volume 47, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 2
- Issue Sort Value:
- 2020-0047-0002-0000
- Page Start:
- 380
- Page End:
- 392
- Publication Date:
- 2019-12-29
- Subjects:
- acceptance -- beam delivery -- commissioning -- MedAustron -- proton -- quality assurance (QA)
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13928 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22046.xml